High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets

Norbertus A Ipenburg iD, Emma M van Oers, Anton C de Groot iD, Mounir Yaâkoubi, Thomas Rustemeyer iD

Contact Dermatitis · 2026-11-02

DOI: 10.1111/cod.70275 ↗

At a glance

Journal article in Contact Dermatitis, published online on 2026-11-02. Written by Norbertus A Ipenburg and 4 co-authors. Institution: Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Center, Amsterdam, the Netherlands. 32 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

SamenvattingSubjectsBibliografische gegevensCiteRelated studies

Abstract (original language)

Background

Patch testing in patients with dermatitis from diabetes devices is challenging because device composition is nearly always undisclosed, relevant allergens are incompletely known, and many suspected allergens are not commercially available.

Objectives

To evaluate the diagnostic yield of a dedicated diabetes device screening series, supplemented with a (meth)acrylate series and testing of patients' own device adhesives and adhesive extracts, in patients with suspected allergic contact dermatitis to glucose sensors, insulin patch pumps, or infusion sets. Materials and Methods We performed a retrospective patch test study of 100 patients referred to a tertiary referral centre for suspected allergic reactions to diabetes devices.

Results

Seventy‐one patients reacted to one or more allergens in the diabetes device screening series; in 50 (70.4%), at least one reaction was clinically relevant. The most frequent relevant allergens were colophonium and its related substances abietic acid and hydroabietyl alcohol, isobornyl acrylate, dicyclohexylmethane‐4,4′‐diisocyanate, and N,N ‐dimethylacrylamide. The (meth)acrylate series had no clear additional diagnostic value. Testing with patients' own device adhesives and extracts frequently identified allergic reactions to devices not recognised by the results of the screening series alone.

Conclusion

The combined approach identified relevant contact allergies in most patients with suspected allergic contact dermatitis to diabetes devices.

Subjects

Author keywords

adhesive extractallergic contact dermatitiscolophoniumdiabetesdicyclohexylmethane‐4,4′‐diisocyanateglucose sensorinsulin pumpisobornyl acrylatepatch testingscreening series

Authors and institutions

  • Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Center, Amsterdam, the Netherlands.
  • Amsterdam University Medical Centers, Amsterdam, the Netherlands.

ORCID profiles: Norbertus A Ipenburg, Anton C de Groot, Thomas Rustemeyer

Cite

APA

Ipenburg, N. A., van Oers, E. M., de Groot, A. C., Yaâkoubi, M., & Rustemeyer, T. (2026). High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets. Contact Dermatitis. https://doi.org/10.1111/cod.70275

Vancouver

Ipenburg NA, van Oers EM, de Groot AC, Yaâkoubi M, Rustemeyer T. High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets. Contact Dermatitis. 2026. doi:10.1111/cod.70275

BibTeX
@article{Ipenburg2026,
  author = {Ipenburg, Norbertus A and van Oers, Emma M and de Groot, Anton C and Yaâkoubi, Mounir and Rustemeyer, Thomas},
  title = {High Diagnostic Yield of Testing With a Diabetes Device Screening Series in Patients With Suspected Allergic Reactions to Glucose Sensors, Insulin Patch Pumps and Insulin Infusion Sets},
  journal = {Contact Dermatitis},
  year = {2026},
  doi = {10.1111/cod.70275}
}
Start for free →