Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers
Contact Dermatitis · 2026-12 · 95 (6) · 557-565
DOI: 10.1111/cod.70246 ↗At a glance
Journal article in Contact Dermatitis, published online on 2026-09-10. Written by Goël Fenech and 5 co-authors. Institution: Department of Occupational and Environmental Diseases, Hotel-Dieu Hospital, APHP. Centre - Université Paris Cité, AP-HP, Paris, France. Major MEDLINE topics: Dermatitis, Allergic Contact, Dermatitis, Occupational, Thiazoles, Thiazolidines. 28 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Background
Over‐ear headphones are a growing source of allergic contact dermatitis (ACD). Identifying well‐known and new culprit sensitizers in such products is challenging because of a lack of labelling and limited cooperation from manufacturers.
Objectives
To report potential skin sensitizers in occupationally‐used headphones from patients attending an occupational allergy clinic. Patients and Methods The over‐ear headphones from two octylisothiazolinone (OIT)‐allergic patients with ear ACD were chemically analysed using ultra performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS).
Results
UPLC–MS/MS confirmed the presence of OIT, but also other biocides (1,2‐benzisothiazolin‐3‐one, cetylpyridinium chloride), rubber accelerators (zinc dibenzyldithiocarbamate, 1,3 diphenyl guanidine, 1,3 di‐ O ‐tolyguanidine, tetramethylthiuram disulfide, tetraethylthiuram disulfide), acrylates (isobornyl acrylate [IBOA]), plasticizers (triphenyl phosphate [TPP], tricresyl phosphate), oxidizers (benzoylperoxide) and organic solvent (dimethylformamide [DMF]).
Conclusions
Over‐ear headphones may contain reproductive toxicant such as DMF, as well as several sensitizers, including TPP, OIT and IBOA. Under the EU REACH Regulation, the use of DMF is restricted, TPP is listed as a Substance of Very High Concern, whereas OIT and IBOA are not subject to specific restriction. Across both occupational and non‐occupational settings, the use of over‐ear headphones may cause contact dermatitis due to exposure to various chemical substances. Our findings may serve to explain these and future cases.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Occupational and Environmental Diseases, Hotel-Dieu Hospital, APHP. Centre - Université Paris Cité, AP-HP, Paris, France.
- Private Practice, Paris, France.
- Polluants Metrology Department, Institut National de Recherche et Sécurité, Vandoeuvre-les-Nancy, France.
- Université Paris Cité, CRESS-INSERM UMR-1153, HERA Team, Paris, France.
ORCID profiles: Goël Fenech, Eddy Langlois, Catherine Champmartin
Cite
APA
Fenech, G., Langlois, E., Pelletier, E., Champmartin, C., Bensefa-Colas, L., & Crepy, M. N. (2026). Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers. Contact Dermatitis, 95(6), 557-565. https://doi.org/10.1111/cod.70246
Vancouver
Fenech G, Langlois E, Pelletier E, Champmartin C, Bensefa-Colas L, Crepy MN. Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers. Contact Dermatitis. 2026;95(6):557-565. doi:10.1111/cod.70246
BibTeX
@article{Fenech2026,
author = {Fenech, Goël and Langlois, Eddy and Pelletier, Eric and Champmartin, Catherine and Bensefa-Colas, Lynda and Crepy, Marie-Noëlle},
title = {Occupational Allergic Contact Dermatitis From Over‐Ear Headphones: Chemical Analysis Reveals Octylisothiazolinone and Other Potential Skin Sensitizers},
journal = {Contact Dermatitis},
year = {2026},
volume = {95},
number = {6},
pages = {557--565},
doi = {10.1111/cod.70246}
}
EUVIMED