EUVIMEDEUVIMED felfedezése
Crossref

The Value of Patch Testing With Stoma Care Products Among Patients With an Ostomy

Emma Louise Gersling Wolff iD, Sebastian Vigand Svendsen iD, Mathilde Nødskov Aguirre Houlberg iD, Line Brok Nørreslet iD, Charlotte G Mortz iD, Kristian Fredløv Mose iD

Contact Dermatitis · 2026

DOI: 10.1111/cod.70094 ↗

At a glance

Journal article in Contact Dermatitis, 2026. Written by Emma Louise Gersling Wolff and 5 co-authors. Institution: Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, Odense C, Denmark. Major MEDLINE topics: Patch Tests, Dermatitis, Allergic Contact, Ostomy, Surgical Stomas. 16 references.

AbsztraktSubjectsBibliográfiai adatokCiteRelated studies

Abstract (original language)

Background

Peristomal skin reactions due to irritant exposure are a common complication of ostomies, whereas contact allergy to stoma care products seems rare. However, knowledge is limited and predominantly based on a few case reports.

Objective

This study evaluated the prevalence of contact allergy to stoma care products and selected contact allergens. Furthermore, reactions were evaluated in relation to demographic and concomitant dermatitis.

Methods

A retrospective analysis of patch test results and clinical data was performed among 98 ostomy patients patch‐tested with their own stoma care products and selected contact allergens between 1992 and 2024 at the Dept. of Dermatology and Allergy Centre, Odense University Hospital, Denmark.

Results

Seven of 98 patch‐tested patients had contact allergy to stoma care products, primarily to ostomy paste ( n = 3). Further, four of 97 patients had a concomitant clinically relevant sensitization to fragrances and preservatives. The prevalence of positive patch test sensitizations did not increase throughout the study period, although approximately fivefold as many patients were patch‐tested in 2018–2024 compared to 1992–2005.

Conclusion

Contact allergy to stoma care products was rare. Despite an increase in the number of patients patch‐tested over a 32‐year period, no increase in the prevalence of contact allergy was observed.

Subjects

MeSH terms (MEDLINE)

Patch TestsDermatitis, Allergic ContactOstomySurgical StomasHumansFemaleMaleRetrospective StudiesMiddle AgedAgedDenmarkPrevalenceAdultAged, 80 and overPersonal Care ProductsPreservatives, PharmaceuticalAllergens

Author keywords

allergic contact dermatitiscontact allergensirritant/toxic exposureostomyperistomal dermatitisstoma care products

Substances

Personal Care ProductsPreservatives, PharmaceuticalAllergens

Authors and institutions

  • Department of Dermatology and Allergy Centre, Odense University Hospital, University of Southern Denmark, Odense C, Denmark.
  • Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense M, Denmark.

ORCID profiles: Emma Louise Gersling Wolff, Sebastian Vigand Svendsen, Mathilde Nødskov Aguirre Houlberg, Line Brok Nørreslet, Charlotte G Mortz, Kristian Fredløv Mose

Cite

APA

Wolff, E. L. G., Svendsen, S. V., Houlberg, M. N. A., Nørreslet, L. B., Mortz, C. G., & Mose, K. F. (2026). The Value of Patch Testing With Stoma Care Products Among Patients With an Ostomy. Contact Dermatitis. https://doi.org/10.1111/cod.70094

Vancouver

Wolff ELG, Svendsen SV, Houlberg MNA, Nørreslet LB, Mortz CG, Mose KF. The Value of Patch Testing With Stoma Care Products Among Patients With an Ostomy. Contact Dermatitis. 2026. doi:10.1111/cod.70094

BibTeX
@article{Wolff2026,
  author = {Wolff, Emma Louise Gersling and Svendsen, Sebastian Vigand and Houlberg, Mathilde Nødskov Aguirre and Nørreslet, Line Brok and Mortz, Charlotte G and Mose, Kristian Fredløv},
  title = {The Value of Patch Testing With Stoma Care Products Among Patients With an Ostomy},
  journal = {Contact Dermatitis},
  year = {2026},
  doi = {10.1111/cod.70094}
}
Start for free →