Journal article in Contact Dermatitis, 2026. Written by Katri Suuronen and 3 co-authors. Institution: Occupational Medicine, Finnish Institute of Occupational Health, Helsinki, Finland. Major MEDLINE topics: Thiazoles, Dermatitis, Allergic Contact, Dermatitis, Occupational, Hand Dermatoses. Cited 5 times so far (Crossref); 17 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Contact allergy to benzisothiazolinone (BIT) has increased in recent years, but exposure to it is not always found. It's important to know whether the gloves might be an isothiazolinone source especially in patients with symptoms from gloves and isothiazolinone contact allergy with or without allergy to rubber chemicals.

Objectives

To present results of chemical analysis of isothiazolinones in disposable rubber gloves of patients in an occupational dermatology clinic.

Methods

We went through our chemical analysis record from 2018–2025 and identified isothiazolinone analyses done from disposable rubber gloves. The chemical analysis of glove extracts was done by liquid chromatography‐mass spectrometry (LC–MS). We screened the respective patients' files and collected information on their occupation, glove usage, patch test reactions as well as basic information on their hand eczema.

Results

We discovered BIT in 30/54 (60%) analysed gloves (27 nitrile rubber gloves, 2 neoprene rubber gloves and 1 natural rubber glove) in concentrations of 0.3–73.7 ppm (mean 12.7 ppm, median 4.2 ppm). Methylisothiazolinone (MI) was found in solitary gloves in small concentrations. Isothiazolinone‐containing gloves were samples from altogether 21 patients, and six of them had several gloves that contained isothiazolinones. Many patients had also other isothiazolinone sources at work or at home.

Conclusions

Disposable rubber gloves are a possible BIT source. Several gloves contained BIT in a concentration that may be enough to induce contact allergy when gloves are used frequently.

Subjects

MeSH terms (MEDLINE)

ThiazolesDermatitis, Allergic ContactDermatitis, OccupationalHand DermatosesRubberGloves, ProtectiveHumansPatch TestsChromatography, LiquidAdultFemaleMale

Author keywords

BITCMI/MIMIOITbenzisothiazolinonechloromethylisothiazolinone/methylisothiazolinonehand dermatitismethylisothiazolinoneoctylisothiazoliononepreservative

Substances

ThiazolesRubber1,2-benzisothiazoline-3-one

Authors and institutions

  • Occupational Medicine, Finnish Institute of Occupational Health, Helsinki, Finland.
  • Work Environment Services, Finnish Institute of Occupational Health, Helsinki, Finland.

ORCID profiles: Katri Suuronen, Sari Suomela, Maria Pesonen

Cite

APA

Suuronen, K., Ylinen, K., Suomela, S., & Pesonen, M. (2026). Isothiazolinones in Disposable Rubber Gloves—Results of Chemical Analysis. Contact Dermatitis. https://doi.org/10.1111/cod.70087

Vancouver

Suuronen K, Ylinen K, Suomela S, Pesonen M. Isothiazolinones in Disposable Rubber Gloves—Results of Chemical Analysis. Contact Dermatitis. 2026. doi:10.1111/cod.70087

BibTeX
@article{Suuronen2026,
  author = {Suuronen, Katri and Ylinen, Katriina and Suomela, Sari and Pesonen, Maria},
  title = {Isothiazolinones in Disposable Rubber Gloves—Results of Chemical Analysis},
  journal = {Contact Dermatitis},
  year = {2026},
  doi = {10.1111/cod.70087}
}
Start for free →