Fallbericht in Contact Dermatitis, published online on 2025-09-13. Written by Blerand Berisha and 3 co-authors. Institution: Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden. Major MEDLINE topics: Dermatitis, Allergic Contact, Thiazoles. Cited 2 times so far (Crossref); 21 references. The full text is freely available (open access, CC BY 4.0).

AchoimreSubjectsSonraí leabharliostaCiteRelated studies

Abstract (original language)

Background

Allergic contact dermatitis (ACD) caused by isothiazolinones is a growing concern, particularly in consumer products. Octylisothiazolinone (OIT) is a potent sensitiser and commonly used as a preservative in rubbers, plastics and coatings, including those found in headphones. Despite increasing regulations on isothiazolinones in cosmetics, their presence in wearable devices remains under‐recognised.

Aims

This investigation aims to identify OIT as a possible sensitiser in patients with presumed ACD due to over‐ear headphones.

Methods

Two patients with presumed ACD due to over‐ear headphones were patch tested at the Department of Occupational and Environmental Dermatology, Skåne University Hospital, Malmö. Patch testing included Swedish baseline series, isothiazolinone compounds, and materials from headphones. To identify potential allergens, chemical analysis of components from headphones was conducted using high‐performance liquid chromatography (HPLC).

Results

Patch testing demonstrated strong positive reactions to OIT in both cases, with additional reactions to acetone extracts of artificial leather and blue plastic foam. OIT remained positive at dilutions as low as 0.00003%. Case 1 also showed positive reactions to MI/MCI. Chemical analysis confirmed OIT in both artificial leather (2.2 mg/g) and plastic foam (0.3 mg/g).

Conclusions

These findings contribute to the understanding of ACD by identifying OIT as a potential allergen in over‐ear headphones. It calls for further research into the prevalence of OIT in consumer electronics and its role in sensitisation.

Subjects

MeSH terms (MEDLINE)

Dermatitis, Allergic ContactThiazolesFemaleHumansMalePatch TestsChildYoung Adult

Author keywords

allergic contact dermatitisoctylisothiazolinoneover‐ear headphonespatch test

Substances

2-n-octyl-4-isothiazolin-3-oneThiazoles

Authors and institutions

  • Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden.
  • Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.

ORCID profiles: Blerand Berisha, Tina Lejding, Ola Bergendorff, Inese Hauksson

Cite

APA

Berisha, B., Lejding, T., Bergendorff, O., & Hauksson, I. (2026). Octylisothiazolinone—A New Sensitizer in Over‐Ear Headphones. Contact Dermatitis, 94(1), 46-51. https://doi.org/10.1111/cod.70028

Vancouver

Berisha B, Lejding T, Bergendorff O, Hauksson I. Octylisothiazolinone—A New Sensitizer in Over‐Ear Headphones. Contact Dermatitis. 2026;94(1):46-51. doi:10.1111/cod.70028

BibTeX
@article{Berisha2026,
  author = {Berisha, Blerand and Lejding, Tina and Bergendorff, Ola and Hauksson, Inese},
  title = {Octylisothiazolinone—A New Sensitizer in Over‐Ear Headphones},
  journal = {Contact Dermatitis},
  year = {2026},
  volume = {94},
  number = {1},
  pages = {46--51},
  doi = {10.1111/cod.70028}
}
Start for free →