EUVIMEDObjevte EUVIMED
ÜbersichtsarbeitOpen access · CC BY-NC-ND 4.0

Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review

Anton de Groot iD, Emma M van Oers, Norbertus A Ipenburg iD, Thomas Rustemeyer iD

Contact Dermatitis · 2025-03 · 92 (3) · 164-175

DOI: 10.1111/cod.14697 ↗

At a glance

Übersichtsarbeit in Contact Dermatitis, published online on 2024-11-26. Written by Anton de Groot and 3 co-authors. Institution: Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Centers, Amsterdam, The Netherlands. Major MEDLINE topics: Blood Glucose Self-Monitoring, Dermatitis, Allergic Contact, Insulin Infusion Systems. Cited 21 times so far (Crossref); 99 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

During the past 8 years, a large number of reports have appeared on allergic contact dermatitis to glucose sensors and insulin pumps in paediatric and adult patients with type 1 diabetes mellitus. Isobornyl acrylate in one particular sensor sensitised many hundreds of (published) individuals, and many other allergens were discovered in a large number of sensors and pumps. Diagnostic procedures with patch tests proved very complicated, as manufacturers showed a serious lack of cooperation with dermatologists in providing information on the ingredients of their products and samples for patch testing. This two part article provides a full and detailed review of all aspects of the subject of allergic contact dermatitis to glucose sensors and insulin pumps. Part 1 provided a general introduction to sensors and pumps, a survey of the cutaneous adverse reactions that they have caused, a full account of the allergens in the diabetes devices and an overview of the glucose sensors and insulin pumps that have caused allergic contact dermatitis. This part 2 presents all published case reports and case series, clinical features of allergic contact dermatitis, patch test procedures, differentiation from irritant dermatitis, management of allergic patients and (proposed) legislation.

Subjects

MeSH terms (MEDLINE)

Blood Glucose Self-MonitoringDermatitis, Allergic ContactInsulin Infusion SystemsAdultFemaleHumansMaleAcrylatesAllergensDermatitis, IrritantDiabetes Mellitus, Type 1Diagnosis, DifferentialPatch TestsCamphanes

Author keywords

N,N‐dimethylacrylamideallergic contact dermatitiscolophoniumcontact allergycontinuous subcutaneous insulin infusiondiabetes medical devicediabetes mellitusglucose monitoringglucose sensorinsulin pumpisobornyl acrylate

Substances

AcrylatesAllergensisobornyl acrylateCamphanes

Authors and institutions

  • Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Centers, Amsterdam, The Netherlands.
  • Amsterdam University Medical Centers, Amsterdam, The Netherlands.

ORCID profiles: Anton de Groot, Norbertus A Ipenburg, Thomas Rustemeyer

Cite

APA

de Groot, A., van Oers, E. M., Ipenburg, N. A., & Rustemeyer, T. (2025). Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review. Contact Dermatitis, 92(3), 164-175. https://doi.org/10.1111/cod.14697

Vancouver

de Groot A, van Oers EM, Ipenburg NA, Rustemeyer T. Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review. Contact Dermatitis. 2025;92(3):164-175. doi:10.1111/cod.14697

BibTeX
@article{deGroot2025,
  author = {de Groot, Anton and van Oers, Emma M and Ipenburg, Norbertus A and Rustemeyer, Thomas},
  title = {Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review},
  journal = {Contact Dermatitis},
  year = {2025},
  volume = {92},
  number = {3},
  pages = {164--175},
  doi = {10.1111/cod.14697}
}
Start for free →