The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies
Contact Dermatitis · 2024
DOI: 10.1111/cod.14481 ↗At a glance
Übersichtsarbeit in Contact Dermatitis, 2024. Written by Chenghao Huang and 2 co-authors. Institution: Calderdale Royal Hospital, Calderdale and Huddersfield NHS Foundation Trust, Halifax, UK. Major MEDLINE topics: Dermatitis, Allergic Contact, Hypersensitivity. Cited 13 times so far (Crossref); 85 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
After almost three‐quarters of a century during which contact dermatologists have often struggled to comprehend the relationship between metal allergy and failure of metal‐alloy containing implant, it is possible to say that a relationship does exist, particularly for cobalt and chromium, but also for nickel. There is still debate as to whether allergy develops as a consequent of failure but thenceforth contributes to it, or whether sensitisation starts first and induces failure secondarily—opinion probably favours the first. Metal‐on‐polypropylene articulations were associated with few metal allergic problems but now are less favoured by orthopaedists due to plastic wear products causing osteolysis and pseudotumour formation through local inflammation. New metal alloys are regularly being introduced such that interested dermatologists need to stay on top of the situation. The jury is still out as to whether the recent favouring of titanium‐containing alloys will confirm them to be more inert allergenically. Case reports do show some clinical reactions to titanium‐containing implants and patch test series have inferred sometimes quite a high background rate of allergy, but interpretation must be tempered by the awareness that titanium salts on patch testing have a tendency to cause irritant reactions. Blood monitoring of metal ion values is now recommended in certain situations after joint replacement and increasing levels may be an indication that allergy with joint failure can develop, in which case patch testing is indicated, and suggested series are available. Predictive patch testing, whilst generally not recommended in the past, has been introduced into some protocols often by non‐dermatologists, such that it is now needed for temporo‐mandibular joint and Nuss bar insertion, and it can be anticipated that this may become more commonplace in the future. One of the major current deficits for patch testers is standardised guidance on which preparation or preparations to use for suspected titanium allergy. One suggestion is 0.5% titanium sulphate in petrolatum, though experience in at least one centre suggests the use of a battery of titanium salts might be desirable.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Calderdale Royal Hospital, Calderdale and Huddersfield NHS Foundation Trust, Halifax, UK.
- Department of Dermatology, Royal Hallamshire Hospital, University of Sheffield, Sheffield, UK.
ORCID profiles: Chenghao Huang, Shu Yu Vanessa Chiang, David J Gawkrodger
Cite
APA
Huang, C., Chiang, S. Y. V., & Gawkrodger, D. J. (2024). The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies. Contact Dermatitis. https://doi.org/10.1111/cod.14481
Vancouver
Huang C, Chiang SYV, Gawkrodger DJ. The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies. Contact Dermatitis. 2024. doi:10.1111/cod.14481
BibTeX
@article{Huang2024,
author = {Huang, Chenghao and Chiang, Shu Yu Vanessa and Gawkrodger, David J},
title = {The contribution of metal allergy to the failure of metal alloy implants, with special reference to titanium: Current knowledge and controversies},