EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial

Zhuo‐Li Huang, Xiao‐Jiao Fu, Chen Sun, Shu‐Jiao Qian, Hong‐Chang Lai, Bei‐Lei Liu, Jun‐Yu Shi

Clinical Oral Implants Research · 18.11.2026

DOI: 10.1111/clr.70204 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 18.11.2026. Verfasst von Zhuo‐Li Huang und 6 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the passive fit, accuracy discrepancy, patient‐reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete‐arch implant‐supported prostheses. Materials and Methods Patients requiring complete‐arch implant‐supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient‐reported outcomes, and operator assessments.

Results

A total of 26 arches (13 in each group) from 17 patients were included. IPG was non‐inferior to CI for passive fit score (adjusted between‐group difference: 95% CI, −0.74–0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort ( p = 0.035), lower anxiety ( p = 0.005), and less nausea ( p = 0.017). Operators reported less interference from patient reactions ( p = 0.020) and greater fluency ( p = 0.035) with IPG.

Conclusion

Within the limitations of the present study, IPG achieved non‐inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete‐arch implant impressions. Trial Registration ClinicalTrials.gov , NCT07190820

Zitieren

APA

Huang, Z., Fu, X., Sun, C., Qian, S., Lai, H., Liu, B., & Shi, J. (2026). Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70204

Vancouver

Huang Z, Fu X, Sun C, Qian S, Lai H, Liu B, et al. Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70204

BibTeX
@article{Huang2026,
  author = {Huang, Zhuo‐Li and Fu, Xiao‐Jiao and Sun, Chen and Qian, Shu‐Jiao and Lai, Hong‐Chang and Liu, Bei‐Lei and Shi, Jun‐Yu},
  title = {Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial},
  journal = {Clinical Oral Implants Research},
  year = {2026},
  doi = {10.1111/clr.70204}
}