EUVIMEDEUVIMED entdecken
Crossref

Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study

Theodoros Tasopoulos, Marta Revilla-León, Abdul B Barmak, Olga Naka, Konstantinos Vazouras iD, Panagiotis Ntovas iD

Clinical Oral Implants Research · 01.11.2026

DOI: 10.1111/clr.70202 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 01.11.2026. Verfasst von Theodoros Tasopoulos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, Athens, Greece. Die Arbeit nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the accuracy of complete‐arch implant scans obtained using non‐splinting and non‐calibrated implant scan body (ISB) methods captured by an intraoral scanner (IOS) with 2 scanning patterns with and without artificial intelligence (AI)‐based tools. Materials and Methods A patient with an edentulous maxillary arch and 4 implants was enrolled. Four groups were established according to scanning technique evaluated: non‐splinting with PEEK or titanium ISBs, 2 non‐calibrated ISBs methods. For each technique, the maxillary arch was scanned using an IOS, applying both a circumferential and an occlusal‐buccal‐lingual scanning pattern, with and without the use of the integrated AI‐based tool of the selected IOS. A stone cast fabricated through the conventional splinted impression was verified and digitized with a laboratory scanner to serve as reference. Linear and angular discrepancies among the designed bars for reference and experimental scans were analyzed.

Results

Non‐calibrated techniques demonstrated better linear trueness and better angular trueness and precision than non‐splinting methods ( p < 0.05). No significant differences were observed between the 2 non‐calibrated ISB techniques ( p > 0.05). The titanium ISBs of the non‐splinting group resulted in better trueness and precision than the PEEK ISBs ( p < 0.05). The AI‐based tool had a significant effect on the accuracy of Dynamic Abutment non‐calibrated ISB system ( p < 0.05). No significant differences were found among the evaluated scanning patterns ( p > 0.05).

Conclusions

Implant scanning technique and AI‐based tool of the IOS selected influenced the accuracy of the complete‐arch implant scans; however, the scanning pattern did not affect the accuracy of the scanning process.

Schlagwörter

Stichwörter der Autor:innen

CAD/CAMfull‐arch prosthesisimplant accuracyimplant acquisitionimplant‐supported restorationscanbody

Autor:innen und Institutionen

  • Private Practice, Athens, Greece.
  • Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.
  • Kois Center, Seattle, Washington, USA.
  • Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.
  • Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
  • Department of Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.

ORCID-Profile: Konstantinos Vazouras, Panagiotis Ntovas

Zitieren

APA

Tasopoulos, T., Revilla-León, M., Barmak, A. B., Naka, O., Vazouras, K., & Ntovas, P. (2026). Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70202

Vancouver

Tasopoulos T, Revilla-León M, Barmak AB, Naka O, Vazouras K, Ntovas P. Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70202

BibTeX
@article{Tasopoulos2026,
  author = {Tasopoulos, Theodoros and Revilla-León, Marta and Barmak, Abdul B and Naka, Olga and Vazouras, Konstantinos and Ntovas, Panagiotis},
  title = {Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study},
  journal = {Clinical Oral Implants Research},
  year = {2026},
  doi = {10.1111/clr.70202}
}
Kostenlos starten →