Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study
Clinical Oral Implants Research · 01.11.2026
DOI: 10.1111/clr.70202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 01.11.2026. Verfasst von Theodoros Tasopoulos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, Athens, Greece. Die Arbeit nennt 52 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the accuracy of complete‐arch implant scans obtained using non‐splinting and non‐calibrated implant scan body (ISB) methods captured by an intraoral scanner (IOS) with 2 scanning patterns with and without artificial intelligence (AI)‐based tools. Materials and Methods A patient with an edentulous maxillary arch and 4 implants was enrolled. Four groups were established according to scanning technique evaluated: non‐splinting with PEEK or titanium ISBs, 2 non‐calibrated ISBs methods. For each technique, the maxillary arch was scanned using an IOS, applying both a circumferential and an occlusal‐buccal‐lingual scanning pattern, with and without the use of the integrated AI‐based tool of the selected IOS. A stone cast fabricated through the conventional splinted impression was verified and digitized with a laboratory scanner to serve as reference. Linear and angular discrepancies among the designed bars for reference and experimental scans were analyzed.
Results
Non‐calibrated techniques demonstrated better linear trueness and better angular trueness and precision than non‐splinting methods ( p < 0.05). No significant differences were observed between the 2 non‐calibrated ISB techniques ( p > 0.05). The titanium ISBs of the non‐splinting group resulted in better trueness and precision than the PEEK ISBs ( p < 0.05). The AI‐based tool had a significant effect on the accuracy of Dynamic Abutment non‐calibrated ISB system ( p < 0.05). No significant differences were found among the evaluated scanning patterns ( p > 0.05).
Conclusions
Implant scanning technique and AI‐based tool of the IOS selected influenced the accuracy of the complete‐arch implant scans; however, the scanning pattern did not affect the accuracy of the scanning process.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Private Practice, Athens, Greece.
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.
- Kois Center, Seattle, Washington, USA.
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA.
- Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA.
- Department of Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.
ORCID-Profile: Konstantinos Vazouras, Panagiotis Ntovas
Zitieren
APA
Tasopoulos, T., Revilla-León, M., Barmak, A. B., Naka, O., Vazouras, K., & Ntovas, P. (2026). Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study. Clinical Oral Implants Research. https://doi.org/10.1111/clr.70202
Vancouver
Tasopoulos T, Revilla-León M, Barmak AB, Naka O, Vazouras K, Ntovas P. Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study. Clinical Oral Implants Research. 2026. doi:10.1111/clr.70202
BibTeX
@article{Tasopoulos2026,
author = {Tasopoulos, Theodoros and Revilla-León, Marta and Barmak, Abdul B and Naka, Olga and Vazouras, Konstantinos and Ntovas, Panagiotis},
title = {Effect of Non‐Splinting Techniques and Non‐Calibrated Implant Scan Body Systems on the Accuracy of Complete‐Arch Implant Scans: A Comparative Clinical Study},
journal = {Clinical Oral Implants Research},
year = {2026},
doi = {10.1111/clr.70202}
}
EUVIMED