Noncalibrated implant scan body system oriented toward the center of the arch: Accuracy of complete arch implant scans recorded using five intraoral scanners
The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · e271-e279
DOI: 10.1016/j.prosdent.2026.03.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Dental Arch, Dental Implants, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Limited studies have assessed the accuracy of noncalibrated implant scan body (ISB) systems for recording implant scans, reporting a reliable method for capturing implant positions. A recently introduced commercial noncalibrated ISB method is available, yet its accuracy remains unknown. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy of complete arch implant scans obtained using a noncalibrated ISB system and 5 intraoral scanners (IOSs). MATERIAL AND METHODS: A stone cast with 6 implant abutment analogs was selected. A laboratory scan was recorded (T710) to obtain the control file. Five groups were described depending on the IOS: Lumina, TRIOS 5, Primescan, i700, and i900. Two subgroups were created based on the technique tested: standard (ISB subgroup) and noncalibrated (NC-ISB subgroup) ISBs (n=15). In the ISB subgroup, an ISB (AB-SR-01 IPD) was tightened into each implant abutment, and scans were captured with the IOSs tested. In the NC-ISB subgroup, a noncalibrated ISB (ScanlogiQ) was hand tightened into each implant abutment toward the center of the arch. Implant scans were recorded involving the pyramid geometry of the noncalibrated ISBs using the IOSs tested. Euclidean linear and angular calculations were obtained for the 6 implants. The measurements acquired in the control scan were used to measure scanning discrepancies with each experimental scan. Two-way ANOVA and the Tukey tests were used to analyze trueness. The Levene test was used to analyze precision (α=.05). RESULTS: Linear trueness discrepancies were found among the groups (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
- Associate Professor, Department of Dental Orthodontics, Faculty of Medicine and Health Sciences, Universidad Católica de Valencia, Valencia, Spain.
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain.
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Zitieren
APA
Revilla-León, M., Guinot-Barona, C., Barmak, A. B., Kois, J. C., Gómez-Polo, M., & Alonso Pérez-Barquero, J. (2026). Noncalibrated implant scan body system oriented toward the center of the arch: Accuracy of complete arch implant scans recorded using five intraoral scanners. The Journal of Prosthetic Dentistry, 136(1), e271-e279. https://doi.org/10.1016/j.prosdent.2026.03.002
Vancouver
Revilla-León M, Guinot-Barona C, Barmak AB, Kois JC, Gómez-Polo M, Alonso Pérez-Barquero J. Noncalibrated implant scan body system oriented toward the center of the arch: Accuracy of complete arch implant scans recorded using five intraoral scanners. The Journal of Prosthetic Dentistry. 2026;136(1):e271-e279. doi:10.1016/j.prosdent.2026.03.002
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Guinot-Barona, Clara and Barmak, Abdul B and Kois, John C and Gómez-Polo, Miguel and Alonso Pérez-Barquero, Jorge},
title = {Noncalibrated implant scan body system oriented toward the center of the arch: Accuracy of complete arch implant scans recorded using five intraoral scanners},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {1},
pages = {e271--e279},
doi = {10.1016/j.prosdent.2026.03.002}
}
EUVIMED