Effect of Crown Design, Cement Type and Margin Depth on the Removal of Cement Remnants Around Single Implant‐Supported Restorations. An In‐Vitro Study
Clinical Oral Implants Research · 2026-07 · 37 (7) · 856-866
DOI: 10.1111/clr.70129 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 12.04.2026. Verfasst von Shaza Bishti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Biomaterials, Centre for Implantology, Uniklinik RWTH Aachen, Aachen, Germany. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Dental Cements, Dental Prosthesis Design. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CAMLOG Foundation.
Abstract (Originalsprache)
Objectives
To assess the influence of crown design, cement type, and margin depth on the removal efficiency of residual cement around single implant‐supported restorations.
Methods
Twelve mandibular models with a missing first molar were fabricated and provided with single implant analogs (centrally/distally placed) and two different crown designs (non‐cantilever/cantilever). Three of each design had either a superficial (SM = −1 mm) or a deep (DM = −2 mm) submucosal margin. Crown restorations were made from CAD/CAM titanium‐base abutments and monolithic zirconia ( n = 120). Three different cements (glass ionomer [GI], polycarboxylate [PC], dual‐curing resin cement [RC]) were used in a standardized way for crown cementation. Ten dentists removed excess cement using metal scalers. The volumetric values of residual cement were calculated (mm 3 ). Statistical analyses assessed the effects of the investigated variables on residual cement volume ( p < 0.05).
Results
The overall analysis showed no significant differences in the volume of cement remnants between both crown designs (non‐cantilever: 0.42 ± 0.96 mm 3 ; cantilever: 0.52 ± 0.98 mm 3 ; p > 0.05). For crown margin depth, a significantly higher cement volume for deeper margins (SM: 0.28 ± 0.62 mm 3 ; DM: 0.68 ± 1.19 mm 3 ; p < 0.05) was found. The highest volume of cement remnants was found in the non‐cantilever_DM_RC (1.19 ± 1.83 mm 3 ), whereas the lowest value was found in non‐cantilever_SM_GI and cantilever_SM_GI (0.00 ± 0.00 mm 3 ). While crown design alone showed no statistically significant effect, its interaction with cement type was associated with improved cement removal in the cantilever group.
Conclusion
Crown margin depth emerged as the dominant factor influencing cement removal. Although cement type also affected residual cement, with glass ionomer showing lower values overall, crown design did not provide a consistent advantage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Uniklinik RWTH Aachen, Aachen, Germany.
ORCID-Profile: Shaza Bishti
Förderung
- CAMLOG Foundation
Zitieren
APA
Bishti, S., Apeldorn, C., Rittich, A., Wolfart, S., & Tuna, T. (2026). Effect of Crown Design, Cement Type and Margin Depth on the Removal of Cement Remnants Around Single Implant‐Supported Restorations. An In‐Vitro Study. Clinical Oral Implants Research, 37(7), 856-866. https://doi.org/10.1111/clr.70129
Vancouver
Bishti S, Apeldorn C, Rittich A, Wolfart S, Tuna T. Effect of Crown Design, Cement Type and Margin Depth on the Removal of Cement Remnants Around Single Implant‐Supported Restorations. An In‐Vitro Study. Clinical Oral Implants Research. 2026;37(7):856-866. doi:10.1111/clr.70129
BibTeX
@article{Bishti2026,
author = {Bishti, Shaza and Apeldorn, Christiane and Rittich, Anne and Wolfart, Stefan and Tuna, Taşkın},
title = {Effect of Crown Design, Cement Type and Margin Depth on the Removal of Cement Remnants Around Single Implant‐Supported Restorations. An In‐Vitro Study},
journal = {Clinical Oral Implants Research},
year = {2026},
volume = {37},
number = {7},
pages = {856--866},
doi = {10.1111/clr.70129}
}
EUVIMED