EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieÄquivalenzstudieOpen Access · CC BY 4.0

A Randomised Controlled Trial Evaluating 3‐Year Survival Rates and Technical Complications of Screw‐Retained Hybrid Abutment Crowns on Two‐Piece Zirconia and Titanium Implants

Guido Sterzenbach iD, Kristin Richter, Klara Alpen, Hediyeh Khoshreza, Florian Beuer iD, Theodor Thiele

Clinical Oral Implants Research · 2025

DOI: 10.1111/clr.14443 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Guido Sterzenbach und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Unive…. Hauptthemen laut MEDLINE: Titanium, Zirconium, Crowns, Dental Restoration Failure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Oral Reconstruction Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study compares the cumulative survival and technical complications of screw‐retained implant‐supported lithium disilicate crowns (SICs) on polyether ketone ketone (PEKK) base abutments and zirconia implants with those of titanium base abutments and titanium implants. Materials and Methods Sixty participants were randomly and evenly assigned to receive zirconia or titanium implants. Survival and technical complications were assessed at 6 weeks after crown placement (baseline) up to 36 months. The cumulative survival of the SICs was analysed as a non‐inferiority design, assuming that the difference between the titanium group and the zirconia group is not more than 10%. Technical complications were assessed based on modified USPHS criteria and Pink Aesthetic Score (PES).

Results

In the zirconia group, three early implant failures occurred; all of them were successfully revised. After baseline, three implants in the zirconia group were lost due to insufficient osseointegration, and therefore the SICs have to be categorised as failures even though none of the SICs failed. The non‐inferiority of the zirconia group could not be confirmed, as the cumulative survival was 10.7% lower compared to the titanium group (100%). The technical complication rate was low, with no statistically significant difference between the groups. The PESs improved significantly compared to baseline, with no significant difference between the groups at 12 months.

Conclusion

Hybrid abutment SICs with PEKK base abutments on two‐piece zirconia implants could be an alternative to hybrid abutments SICs with titanium base on titanium implants. However, the lower osseointegration rate of the zirconia implants has to be considered. Trial Registration: This study was registered in the German Clinical Trial Register (Deutsches Register Klinischer Studien) (number: DRKS00014866)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumZirconiumCrownsDental Restoration FailureDental Prosthesis, Implant-SupportedDental AbutmentsDental Implant-Abutment DesignDental ImplantsHumansMaleFemaleMiddle AgedAdultDental Prosthesis DesignDental Porcelain

Stichwörter der Autor:innen

ceramic implantshybrid abutment crownrandomised controlled trialscrew‐retainedtitaniumtwo‐piece implantszirconia

Substanzen

TitaniumZirconiumzirconium oxideDental Implantslithia disilicateDental Porcelain

Autor:innen und Institutionen

  • Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of…
  • MVZ Zahnmedizin Pankow, Dentalzentrum Pankow, Berlin, Germany.

ORCID-Profile: Guido Sterzenbach, Florian Beuer

Förderung

  • Oral Reconstruction Foundation

Zitieren

APA

Sterzenbach, G., Richter, K., Alpen, K., Khoshreza, H., Beuer, F., & Thiele, T. (2025). A Randomised Controlled Trial Evaluating 3‐Year Survival Rates and Technical Complications of Screw‐Retained Hybrid Abutment Crowns on Two‐Piece Zirconia and Titanium Implants. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14443

Vancouver

Sterzenbach G, Richter K, Alpen K, Khoshreza H, Beuer F, Thiele T. A Randomised Controlled Trial Evaluating 3‐Year Survival Rates and Technical Complications of Screw‐Retained Hybrid Abutment Crowns on Two‐Piece Zirconia and Titanium Implants. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14443

BibTeX
@article{Sterzenbach2025,
  author = {Sterzenbach, Guido and Richter, Kristin and Alpen, Klara and Khoshreza, Hediyeh and Beuer, Florian and Thiele, Theodor},
  title = {A Randomised Controlled Trial Evaluating 3‐Year Survival Rates and Technical Complications of Screw‐Retained Hybrid Abutment Crowns on Two‐Piece Zirconia and Titanium Implants},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  doi = {10.1111/clr.14443}
}
Kostenlos starten →