Systematische Übersicht in der Zeitschrift Clinical Oral Implants Research, online erschienen am 12.04.2025. Verfasst von Krisztina Mikulás und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Semmelweis University, Budapest, Hungary. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Prosthesis, Implant-Supported, Digital Technology. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Semmelweis Egyetem.
Abstract (Originalsprache)
Background
Accurately replicating the emergence profile (EP) of conditioned soft tissue is pivotal for the success of implant‐supported restorations. In the field of digital technology, various methods have emerged to capture EP. This review aims to critically assess current digital methodologies for capturing peri‐implant EP. Material and Methods Prospective interventional or observational clinical studies focusing on digitally mapping the emergence profile (EP) around single implant‐supported restorations were included. Systematic reviews, in vitro and animal studies, and those not emphasizing EP capture were excluded. A systematic search across four databases (MEDLINE, CENTRAL, Embase, Web of Science) was conducted on 7th August 2024 based on a previously registered protocol (PROSPERO registration number: CRD42023459484). Risk of bias was assessed with RoB 2, ROBINS‐I, and JBI critical appraisal tools. Qualitative and quantitative analyses were carried out.
Results
Twenty‐four eligible studies were identified, comprising 5 dental techniques, 12 case reports, 1 randomized controlled study, 2 cross‐sectional studies, and 4 cross‐over studies. The studies reported semi‐digital pathways, direct scanning, indirect scanning, coded‐healing abutments, and individualized use of scan bodies. Notably, the direct scanning technique showed considerable soft tissue collapse. Similar results can be achieved with indirect scanning and the conventional method.
Conclusions
Indirect EP scanning appears as the most promising method for capturing peri‐implant EP. However, a confirmation of this finding requires a quantitative analysis through randomized clinical trials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary.
- Institute of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary.
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.
- Section of Graduate Periodontology, Faculty of Odontology, Universidad Complutense de Madrid, Spain.
ORCID-Profile: Xinyi Qian, Gergely Agócs, German O Gallucci, Ignacio Pedrinaci
Förderung
- Semmelweis Egyetem
Zitieren
APA
Mikulás, K., Qian, X., Tajti, P., Agócs, G., Gallucci, G. O., Pedrinaci, I., & Hermann, P. (2025). Accuracy of Digital Impression Methods for Capturing the Peri‐Implant Emergence Profile: A Systematic Review. Clinical Oral Implants Research, 36(8), 930-943. https://doi.org/10.1111/clr.14441
Vancouver
Mikulás K, Qian X, Tajti P, Agócs G, Gallucci GO, Pedrinaci I, et al. Accuracy of Digital Impression Methods for Capturing the Peri‐Implant Emergence Profile: A Systematic Review. Clinical Oral Implants Research. 2025;36(8):930-943. doi:10.1111/clr.14441
BibTeX
@article{Mikuls2025,
author = {Mikulás, Krisztina and Qian, Xinyi and Tajti, Péter and Agócs, Gergely and Gallucci, German O and Pedrinaci, Ignacio and Hermann, Péter},
title = {Accuracy of Digital Impression Methods for Capturing the Peri‐Implant Emergence Profile: A Systematic Review},
journal = {Clinical Oral Implants Research},
year = {2025},
volume = {36},
number = {8},
pages = {930--943},
doi = {10.1111/clr.14441}
}
EUVIMED