Implant‐Supported Cantilever Fixed Dental Prosthesis in the Anterior Region: Effect of Implant Type and Aging In Vitro

Nadja Rohr iD, Yotaro Iwauchi iD, Raffael Bernauer, Raphael Heuzeroth, Nicola U Zitzmann iD

Clinical Oral Implants Research · 2025

DOI: 10.1111/clr.14388 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2025. Verfasst von Nadja Rohr und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland. Hauptthemen laut MEDLINE: Dental Prosthesis, Implant-Supported, Dental Implants, Denture, Partial, Fixed. Die Arbeit nennt 31 Literaturangaben. Gefördert von: ITI Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To investigate if the fracture load of implant‐supported cantilever fixed dental prostheses (ICFDPs) in the anterior region is affected by the implant type and the aging protocol. Materials and Methods Sixty ICFDPs were prepared using multilayer monolithic zirconia for restoring bone‐level (BL) and tissue‐level (TL) titanium‐zirconium implants. Fracture load was measured at baseline (no aging) or after aging in a chewing simulator loading the implant crown or the cantilever in a 30° angle ( n = 10 per group). A two‐way ANOVA was applied ( α = 0.05) for the effects of implant type and aging protocol.

Results

Implant type ( p < 0.001) and aging ( p < 0.001) had a significant effect on fracture load values. Baseline specimens of both BL (665 ± 62 N) and TL (554 ± 23 N) had significantly higher mean fracture load values than those of aged specimens(BL implant crown 545 ± 46 N, BL cantilever 563 ± 45 N, TL implant crown 455 ± 32 N, TL cantilever 476 ± 24 N) ( p < 0.001). The loading position during aging did not affect fracture load values for BL ( p = 0.980) nor TL ( p = 0.749). BL implants failed by cement fracture and abutment deformation, while for TL the transmucosal part of the implant deformed.

Conclusions

The fracture load values of anterior ICFDPs decrease with aging in a chewing simulator. BL implants are preferable over TL implants for anterior ICFDPs as higher fracture load values were achieved, and no implant deformation occurred.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Prosthesis, Implant-SupportedDental ImplantsDenture, Partial, FixedDental Stress AnalysisHumansDental Restoration FailureZirconiumIn Vitro TechniquesCrownsTitaniumDental Prosthesis DesignMaterials Testing

Stichwörter der Autor:innen

cantileverchewing simulationfracture loadimplantzirconia

Substanzen

Dental Implantszirconium oxideZirconiumTitanium

Autor:innen und Institutionen

  • Department of Reconstructive Dentistry, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland.
  • Biomaterials and Technology, Department of Research, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland.

ORCID-Profile: Nadja Rohr, Yotaro Iwauchi, Nicola U Zitzmann

Förderung

  • ITI Foundation

Zitieren

APA

Rohr, N., Iwauchi, Y., Bernauer, R., Heuzeroth, R., & Zitzmann, N. U. (2025). Implant‐Supported Cantilever Fixed Dental Prosthesis in the Anterior Region: Effect of Implant Type and Aging In Vitro. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14388

Vancouver

Rohr N, Iwauchi Y, Bernauer R, Heuzeroth R, Zitzmann NU. Implant‐Supported Cantilever Fixed Dental Prosthesis in the Anterior Region: Effect of Implant Type and Aging In Vitro. Clinical Oral Implants Research. 2025. doi:10.1111/clr.14388

BibTeX
@article{Rohr2025,
  author = {Rohr, Nadja and Iwauchi, Yotaro and Bernauer, Raffael and Heuzeroth, Raphael and Zitzmann, Nicola U},
  title = {Implant‐Supported Cantilever Fixed Dental Prosthesis in the Anterior Region: Effect of Implant Type and Aging In Vitro},
  journal = {Clinical Oral Implants Research},
  year = {2025},
  doi = {10.1111/clr.14388}
}
Kostenlos starten →