EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC 4.0

Validation of a novel AI ‐based automated multimodal image registration of CBCT and intraoral scan aiding presurgical implant planning

Bahaaeldeen M Elgarba iD, Rocharles Cavalcante Fontenele iD, Saleem Ali iD, Abdullah Swaity iD, Jan Meeus iD, Sohaib Shujaat iD, Reinhilde Jacobs iD

Clinical Oral Implants Research · 2024-11 · 35 (11) · 1506-1517

DOI: 10.1111/clr.14338 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Clinical Oral Implants Research, online erschienen am 05.08.2024. Verfasst von Bahaaeldeen M Elgarba und 6 weiteren Autor:innen. Beteiligte Einrichtung: OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven & Department of Oral and Maxillofacial Surgery, Unive…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Artificial Intelligence. Die Arbeit wurde bisher 42-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The objective of this study is to assess accuracy, time‐efficiency and consistency of a novel artificial intelligence (AI)‐driven automated tool for cone‐beam computed tomography (CBCT) and intraoral scan (IOS) registration compared with manual and semi‐automated approaches. Materials and Methods A dataset of 31 intraoral scans (IOSs) and CBCT scans was used to validate automated IOS‐CBCT registration (AR) when compared with manual (MR) and semi‐automated registration (SR). CBCT scans were conducted by placing cotton rolls between the cheeks and teeth to facilitate gingival delineation. The time taken to perform multimodal registration was recorded in seconds. A qualitative analysis was carried out to assess the correspondence between hard and soft tissue anatomy on IOS and CBCT. In addition, a quantitative analysis was conducted by measuring median surface deviation (MSD) and root mean square (RMS) differences between registered IOSs.

Results

AR was the most time‐efficient, taking 51.4 ± 17.2 s, compared with MR (840 ± 168.9 s) and SR approaches (274.7 ± 100.7 s). Both AR and SR resulted in significantly higher qualitative scores, favoring perfect IOS‐CBCT registration, compared with MR ( p = .001). Additionally, AR demonstrated significantly superior quantitative performance compared with SR, as indicated by low MSD (0.04 ± 0.07 mm) and RMS (0.19 ± 0.31 mm). In contrast, MR exhibited a significantly higher discrepancy compared with both AR (MSD = 0.13 ± 0.20 mm; RMS = 0.32 ± 0.14 mm) and SR (MSD = 0.11 ± 0.15 mm; RMS = 0.40 ± 0.30 mm).

Conclusions

The novel AI‐driven method provided an accurate, time‐efficient, and consistent multimodal IOS‐CBCT registration, encompassing both soft and hard tissues. This approach stands as a valuable alternative to manual and semi‐automated registration approaches in the presurgical implant planning workflow.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyArtificial IntelligenceHumansMultimodal ImagingPatient Care Planning

Stichwörter der Autor:innen

artificial intelligencecone‐beam computed tomographydeep learningimaging, three‐dimensionalmultimodal imaging

Autor:innen und Institutionen

  • OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven & Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
  • Department of Prosthodontics, Faculty of Dentistry, Tanta University, Tanta, Egypt.
  • King Hussein Medical Center, Jordanian Royal Medical Services, Amman, Jordan.
  • Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
  • King Abdullah International Medical Research Center, Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Ministry of National Guard…
  • Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden.

ORCID-Profile: Bahaaeldeen M Elgarba, Rocharles Cavalcante Fontenele, Saleem Ali, Abdullah Swaity, Jan Meeus, Sohaib Shujaat, Reinhilde Jacobs

Zitieren

APA

Elgarba, B. M., Fontenele, R. C., Ali, S., Swaity, A., Meeus, J., Shujaat, S., & Jacobs, R. (2024). Validation of a novel AI ‐based automated multimodal image registration of CBCT and intraoral scan aiding presurgical implant planning. Clinical Oral Implants Research, 35(11), 1506-1517. https://doi.org/10.1111/clr.14338

Vancouver

Elgarba BM, Fontenele RC, Ali S, Swaity A, Meeus J, Shujaat S, et al. Validation of a novel AI ‐based automated multimodal image registration of CBCT and intraoral scan aiding presurgical implant planning. Clinical Oral Implants Research. 2024;35(11):1506-1517. doi:10.1111/clr.14338

BibTeX
@article{Elgarba2024,
  author = {Elgarba, Bahaaeldeen M and Fontenele, Rocharles Cavalcante and Ali, Saleem and Swaity, Abdullah and Meeus, Jan and Shujaat, Sohaib and Jacobs, Reinhilde},
  title = {Validation of a novel AI ‐based automated multimodal image registration of CBCT and intraoral scan aiding presurgical implant planning},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  volume = {35},
  number = {11},
  pages = {1506--1517},
  doi = {10.1111/clr.14338}
}
Kostenlos starten →