EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A cross‐sectional CBCT assessment of the relative position of one‐piece titanium‐zirconium mini‐implants placed for mandibular overdentures using non‐guided surgery

Cláudio Rodrigues Leles iD, Leuçon de Oliveira Moura-Neto, Jésio Rodrigues Silva iD, Lays Noleto Nascimento, Thalita Fernandes Fleury Curado iD, Nadia Lago Costa iD, Martin Schimmel iD, Gerald McKenna iD

Clinical Oral Implants Research · 2024

DOI: 10.1111/clr.14335 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2024. Verfasst von Cláudio Rodrigues Leles und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, Federal University of Goias, Goiania, Brazil. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Denture, Overlay, Mandible, Titanium. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the relative position of mini‐implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors.

Methods

Mandibular cone‐beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one‐piece titanium‐zirconium mini‐implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post‐insertion CBCT images in DICOM format were analyzed using the E‐Vol‐DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software.

Results

Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections ( p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively ( p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection ( p < .001), greater distance between the paired implants ( p = .017), the flapped surgical protocol ( p = .002), higher final insertion torque ( p = .011), and deeper preparation with the needle drill ( p < .001).

Conclusions

The mini‐implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini‐implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyDenture, OverlayMandibleTitaniumDental ImplantsZirconiumHumansMaleFemaleMiddle AgedAgedCross-Sectional StudiesDental Prosthesis, Implant-SupportedDental Implantation, EndosseousAged, 80 and over

Stichwörter der Autor:innen

cone‐beam computed tomographydental implantimplant surgeryoverdenture

Substanzen

TitaniumDental ImplantsZirconium

Autor:innen und Institutionen

  • School of Dentistry, Federal University of Goias, Goiania, Brazil.
  • Division of Gerodontology, Department of Reconstructive Dentistry, School of Dental Medicine of the University of Bern, Bern, Switzerland.
  • Clinic of General-, Special Care- and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
  • Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Centre for Public Health, Queen's University Belfast, Belfast, UK.

ORCID-Profile: Cláudio Rodrigues Leles, Jésio Rodrigues Silva, Thalita Fernandes Fleury Curado, Nadia Lago Costa, Martin Schimmel, Gerald McKenna

Zitieren

APA

Leles, C. R., de Oliveira Moura-Neto, L., Silva, J. R., Nascimento, L. N., Curado, T. F. F., Costa, N. L., Schimmel, M., & McKenna, G. (2024). A cross‐sectional CBCT assessment of the relative position of one‐piece titanium‐zirconium mini‐implants placed for mandibular overdentures using non‐guided surgery. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14335

Vancouver

Leles CR, de Oliveira Moura-Neto L, Silva JR, Nascimento LN, Curado TFF, Costa NL, et al. A cross‐sectional CBCT assessment of the relative position of one‐piece titanium‐zirconium mini‐implants placed for mandibular overdentures using non‐guided surgery. Clinical Oral Implants Research. 2024. doi:10.1111/clr.14335

BibTeX
@article{Leles2024,
  author = {Leles, Cláudio Rodrigues and de Oliveira Moura-Neto, Leuçon and Silva, Jésio Rodrigues and Nascimento, Lays Noleto and Curado, Thalita Fernandes Fleury and Costa, Nadia Lago and Schimmel, Martin and McKenna, Gerald},
  title = {A cross‐sectional CBCT assessment of the relative position of one‐piece titanium‐zirconium mini‐implants placed for mandibular overdentures using non‐guided surgery},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  doi = {10.1111/clr.14335}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche