EUVIMEDEUVIMED entdecken
Crossref

Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium‐zirconium mini‐implants for overdentures: A cross‐sectional analysis

Cláudio Rodrigues Leles iD, José Luiz Rodrigues Leles, Thalita Fernandes Fleury Curado iD, Jésio Rodrigues Silva iD, Lays Noleto Nascimento, Marcella Silva de Paula iD, Sabrina Maniewicz iD, Martin Schimmel iD, Gerald McKenna iD

Clinical Implant Dentistry and Related Research · 2023

DOI: 10.1111/cid.13181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2023. Verfasst von Cláudio Rodrigues Leles und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, Federal University of Goias, Goiania, Goias, Brazil. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Dental Implants. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: International Team for Implantology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to assess the final insertion torque values achieved using site‐specific drilling protocols for a novel mini implant system for removable complete overdentures. Anatomical and technical factors influencing final insertion torque were recorded and analyzed. Material and Methods Participants were randomized to two surgical protocol groups (flapped or flapless) and all received four mini implants (Straumann® mini implant system; Straumann AG) in the anterior mandible, using a 1.6 mm needle drill and a 2.2 mm pilot drill for the implant bed site preparation. The final insertion torque was recorded as the main outcome variable during surgery. Bone type, radiographical bone density, ridge form, implant length, and the drilling protocol were considered as independent variables. Descriptive statistics, generalized estimating equations (GEE) regression, and heatmap charts were used for data analyses.

Results

A total of 296 mini implants were placed in 74 patients (mean age = 64.1 ± 8.0; 64.9% female) using flapless ( n = 37) or flapped ( n = 37) surgeries. Mean final insertion torque was 55.8 ± 18.4 Ncm (10.5% > 35 Ncm, 48.9% between 35 and 65 Ncm, and 40.6% > 65 Ncm). The needle drill was used in only 43.9% of the implant bed sites. Higher final torque values were observed for higher bone densities (bone type I > II > III, and D1–D2 > D3–D4), highly resorbed ridge forms (5–6 > 3–4), flapped surgeries, and male patients. However, regression models showed that the likelihood of achieving optimal insertion torque (≥35 and ≤65 Ncm) was higher for females (OR = 2.14; 95%CI = 1.14–4.01; p = 0.018), ridge forms 3–4 (OR = 2.87; 95%CI = 1.05–7.85; p = 0.040), and flapless surgeries (OR = 1.96; 95%CI = 1.09–3.51; p = 0.024).

Conclusions

Sufficient primary stability for immediate loading was achieved for the majority of the mini implants placed. Surgical implant bed preparation should be site‐specific to achieve optimal primary stability for immediate loading while avoiding excessive insertion torque.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousDental ImplantsHumansMaleFemaleMiddle AgedAgedTitaniumCross-Sectional StudiesZirconiumTorqueDenture, OverlayMandibleRandomized Controlled Trials as Topic

Stichwörter der Autor:innen

clinical studydental implantedentulous mandibleoverdenture

Substanzen

Dental ImplantsTitaniumZirconium

Autor:innen und Institutionen

  • School of Dentistry, Federal University of Goias, Goiania, Goias, Brazil.
  • School of Dentistry, Paulista University, Goiania, Goias, Brazil.
  • Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Consultant in Restorative Dentistry, Centre for Public Health, Queen's University Belfast, Belfast, UK.

ORCID-Profile: Cláudio Rodrigues Leles, Thalita Fernandes Fleury Curado, Jésio Rodrigues Silva, Marcella Silva de Paula, Sabrina Maniewicz, Martin Schimmel, Gerald McKenna

Förderung

  • International Team for Implantology

Zitieren

APA

Leles, C. R., Leles, J. L. R., Curado, T. F. F., Silva, J. R., Nascimento, L. N., de Paula, M. S., Maniewicz, S., Schimmel, M., & McKenna, G. (2023). Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium‐zirconium mini‐implants for overdentures: A cross‐sectional analysis. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.13181

Vancouver

Leles CR, Leles JLR, Curado TFF, Silva JR, Nascimento LN, de Paula MS, et al. Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium‐zirconium mini‐implants for overdentures: A cross‐sectional analysis. Clinical Implant Dentistry and Related Research. 2023. doi:10.1111/cid.13181

BibTeX
@article{Leles2023,
  author = {Leles, Cláudio Rodrigues and Leles, José Luiz Rodrigues and Curado, Thalita Fernandes Fleury and Silva, Jésio Rodrigues and Nascimento, Lays Noleto and de Paula, Marcella Silva and Maniewicz, Sabrina and Schimmel, Martin and McKenna, Gerald},
  title = {Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium‐zirconium mini‐implants for overdentures: A cross‐sectional analysis},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2023},
  doi = {10.1111/cid.13181}
}
Kostenlos starten →