Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 05.07.2024. Verfasst von Laurits Kaaber und 3 weiteren Autor:innen. Beteiligte Einrichtung: Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus C, Denmark. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Alveolar Process, Cadaver, Mandible. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To evaluate the performance of low‐dose cone beam computed tomography (CBCT) protocols with regard to linear bone measurements in the posterior mandible for implant planning compared with higher dose protocols. Materials and Methods Forty‐two edentulous posterior sites in human cadaveric mandibles were imaged in three CBCT scanners using three or four protocols with varying exposure parameters to achieve lower dose. Co‐registration was performed to generate sagittal and cross‐sectional image sections representative of the implant site. Three observers measured bone height, from the alveolar crest to the mandibular canal, and width, three mm from the top of the alveolar crest. Intra‐ and interobserver reproducibility were assessed for the cases rated as nonmeasurable as well as for completed measurements. The measurements were analyzed using paired t ‐tests for differences among the CBCT protocols and the frequency distribution of nonmeasurable cases with a Pearson Chi‐square test.

Results

Reproducibility for registering nonmeasurable cases varied among observers; however, no consistent significant differences were found in the frequency distribution of these cases among observers, units, and protocols. Intraclass correlation coefficients (ICC) were >0.9 for all measurements of bone height and width. Mean differences of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyAlveolar ProcessCadaverMandibleHumansReproducibility of ResultsRadiation DosageDental Implantation, EndosseousJaw, EdentulousPatient Care Planning

Stichwörter der Autor:innen

alveolar bone measurementscone beam computed tomographydental implantsradiation protection

Autor:innen und Institutionen

  • Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus C, Denmark.

ORCID-Profile: Laurits Kaaber, Rubens Spin-Neto

Zitieren

APA

Kaaber, L., Matzen, L. H., Spin-Neto, R., & Schropp, L. (2024). Low‐dose, standard, and high‐resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Clinical Oral Implants Research, 35(11), 1394-1405. https://doi.org/10.1111/clr.14326

Vancouver

Kaaber L, Matzen LH, Spin-Neto R, Schropp L. Low‐dose, standard, and high‐resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens. Clinical Oral Implants Research. 2024;35(11):1394-1405. doi:10.1111/clr.14326

BibTeX
@article{Kaaber2024,
  author = {Kaaber, Laurits and Matzen, Louise Hauge and Spin-Neto, Rubens and Schropp, Lars},
  title = {Low‐dose, standard, and high‐resolution cone beam computed tomography for alveolar bone measurements related to implant planning: An ex vivo study in human specimens},
  journal = {Clinical Oral Implants Research},
  year = {2024},
  volume = {35},
  number = {11},
  pages = {1394--1405},
  doi = {10.1111/clr.14326}
}
Kostenlos starten →