The influence of guide stabilizers and their application sequences on trueness and precision of surgical guides in free end situations: An in vitro analysis
Clinical Oral Implants Research · 2024-03 · 35 (3) · 294-304
DOI: 10.1111/clr.14226 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Implants Research, online erschienen am 19.12.2023. Verfasst von Runheng Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University and Guangdong Provincial Clinical Research Center of Oral Diseases, G…. Hauptthemen laut MEDLINE: Dental Implants, Surgery, Computer-Assisted, Mouth, Edentulous, Tooth Loss. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangdong Basic and Applied Basic Research Foundation, Science and Technology Program of Guangzhou, China.
Abstract (Originalsprache)
Objectives
To evaluate the impact of guide stabilizers and their application sequences on implant placement accuracy of guided implant surgery in multiple teeth loss at free end. Materials and Methods In this study, 96 implants were placed in the regions of #34, #36, and #37 of 32 identical mandibular models. The influence of using guide stabilizers or not (group A and group B) and various guide stabilizers application sequences (group B: #34 → #36 → #37; group C: #36 → #34 → #37; group D: #37 → #34 → #36) on implant placement trueness and precision was investigated. Data were analyzed using T ‐tests and one‐way ANOVA.
Results
Group B showed significant benefits in enhancing implant placement precision. Compared to group A, it resulted in reducing 3D‐deviation at crest and 2D deviation in vestibular‐oral direction at both crest and apex. Furthermore, group D demonstrated greater improvement in global implant placement precision by reducing 2D deviation in mesial‐distal direction at both crest and apex. Among the three different stabilizer application sequences, group D exhibited the highest level of implant placement precision.
Conclusions
In cases of missing teeth at distal free end, the use of guide stabilizers and their application sequences does not have a significant impact on implant placement trueness. However, they do improve implant placement precision compared to methods that do not utilize guide stabilizers. Specifically, applying a guide stabilizer first at the furthest implant site to change teeth loss classification from free end to edentulous space with posterior support is the most reliable sequence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University and Guangdong Provincial Clinical Research Center of Oral Diseases, Guangzhou, China.
ORCID-Profile: Ruidi Xia, Quan Liu, Zetao Chen
Förderung
- National Natural Science Foundation of China
- Guangdong Basic and Applied Basic Research Foundation
- Science and Technology Program of Guangzhou, China
- Guangdong Financial Fund for High-Caliber Hospital Construction, and National Undergraduate Training Program for Innovation and Entrepreneurship
- Special Funds for the Cultivation of Guangdong College Students' Scientific and Technological Innovation
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Liu, R., Xia, R., Zhang, L., Gan, X., Li, C., Liu, Q., Chen, Z., & Chen, Z. (2024). The influence of guide stabilizers and their application sequences on trueness and precision of surgical guides in free end situations: An in vitro analysis. Clinical Oral Implants Research, 35(3), 294-304. https://doi.org/10.1111/clr.14226
Vancouver
Liu R, Xia R, Zhang L, Gan X, Li C, Liu Q, et al. The influence of guide stabilizers and their application sequences on trueness and precision of surgical guides in free end situations: An in vitro analysis. Clinical Oral Implants Research. 2024;35(3):294-304. doi:10.1111/clr.14226
BibTeX
@article{Liu2024,
author = {Liu, Runheng and Xia, Ruidi and Zhang, Linjun and Gan, Xuejing and Li, Cuijun and Liu, Quan and Chen, Zhuofan and Chen, Zetao},
title = {The influence of guide stabilizers and their application sequences on trueness and precision of surgical guides in free end situations: An in vitro analysis},
journal = {Clinical Oral Implants Research},
year = {2024},
volume = {35},
number = {3},
pages = {294--304},
doi = {10.1111/clr.14226}
}
EUVIMED