Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study
The Journal of Prosthetic Dentistry · 2024-09 · 132 (3) · 602.e1-602.e9
DOI: 10.1016/j.prosdent.2024.06.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-09. Verfasst von Min Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine…. Hauptthemen laut MEDLINE: Photogrammetry, Dental Prosthesis, Implant-Supported, Dental Impression Technique. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Conventional impression techniques for complete arch implant-supported fixed dental prostheses (CIFDPs) are technique sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer alternatives to conventional impression making. PURPOSE: The purpose of this in vitro study was to assess the accuracy and passive fit of IOS with prefabricated aids, SPG, and open tray impression (OI) for CIFDPs with different implant distributions. MATERIAL AND METHODS: Three definitive casts with 4 parallel implants (4-PARA), 4 inclined implants (4-INCL), and 6 parallel implants (6-PARA) were fabricated. Three recording techniques were tested: IOS with prefabricated aids, SPG, and OI. The best and the worst scans were selected to fabricate 18 milled aluminum alloy frameworks. The trueness and precision of distance deviation (∆td and ∆pd), angular deviation (∆tθand ∆pθ), root mean square errors (∆tRMS for ∆pRMS), and passive fit score of frameworks were recorded. Two-way ANOVA was applied. RESULTS: SPG showed the best trueness and precision (95%CI of ∆td/∆tθ/∆tRMS, 31 to 39 µm, 0.22 to 0.28 degrees, 20 to 23 µm; 95%CI of ∆pd/∆pθ/∆pRMS, 9 to 11 µm, 0.06 to 0.08 degrees, 8 to 10 µm), followed by OI (61 to 83 µm, 0.33 to 0.48 degrees, 28 to 48 µm; 66 to 81 µm, 0.29 to 0.38 degrees, 32 to 41 µm) and IOS (143 to 193 µm, 0.37 to 0.50 degrees, 81 to 96 µm; 89 to 111 µm, 0.27 to 0.31 degrees, 51 to 62 µm). Tilted implants were associated with increased distance deviation. Increased implant number was associated with improved recording precision. The passive fit of frameworks was negatively correlated with the RMS error, and the correlation coefficient was -0.65 (P=.003). CONCLUSIONS: SPG had the best accuracy. Implant distributions affected implant precision. The RMS error can be used to evaluate the passive fit of frameworks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Resident, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key La…
- Professor, Department of Prosthodontics, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for…
- Associate Researcher, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Sha…
- Attending, Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key L…
Zitieren
APA
Liu, M., Fu, X. J., Lai, H. C., Shi, J. Y., & Liu, B. L. (2024). Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study. The Journal of Prosthetic Dentistry, 132(3), 602.e1-602.e9. https://doi.org/10.1016/j.prosdent.2024.06.006
Vancouver
Liu M, Fu XJ, Lai HC, Shi JY, Liu BL. Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study. The Journal of Prosthetic Dentistry. 2024;132(3):602.e1-602.e9. doi:10.1016/j.prosdent.2024.06.006
BibTeX
@article{Liu2024,
author = {Liu, Min and Fu, Xiao-Jiao and Lai, Hong-Chang and Shi, Jun-Yu and Liu, Bei-Lei},
title = {Accuracy of traditional open-tray impression, stereophotogrammetry, and intraoral scanning with prefabricated aids for implant-supported complete arch prostheses with different implant distributions: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {3},
pages = {602.e1--602.e9},
doi = {10.1016/j.prosdent.2024.06.006}
}