Fachartikel in der Zeitschrift Clinical Oral Implants Research, 2023. Verfasst von Bin-Zhang Wu und 3 weiteren Autor:innen. Beteiligte Einrichtung: First Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center f…. Hauptthemen laut MEDLINE: Dental Implants, Surgery, Computer-Assisted, Tooth. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology, School of Stomatology, Peking University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the relative accuracy of manual (U‐shaped tube) and automatic (two‐in‐one) dynamic navigation registration techniques for implant surgery performed in posterior sites missing one tooth. Materials and Methods This study included 58 partially edentulous patients with 58 implants, including 31 and 27 in the manual and automatic groups. Deviations between the planned and actual implant placement were assessed.

Results

The angular deviation in the overall study cohort was 2.54 ± 1.21°, while the 3D deviations at the implant platform and apex were 0.90 ± 0.46 mm and 1.04 ± 0.47 mm, respectively. The respective angular deviations in the manual and automatic groups were 2.82 ± 1.17° and 2.21 ± 1.19° ( p > .05), while platform deviations were 0.89 ± 0.48 mm and 0.91 ± 0.45 mm ( p > .05), and apex deviations were 0.99 ± 0.48 mm and 1.11 ± 0.46 mm ( p > .05). No significant differences in absolute buccolingual, mesiodistal, or apicocoronal deviations were detected between these groups at either level ( p > .05) nor were did deviation distributions differ in the buccolingual, mesiodistal, or apicocoronal directions at the platform or apex levels ( p > .05).

Conclusions

Manual and automatic dynamic navigation registration techniques can achieve excellent accuracy when placing implants in posterior sites missing a single tooth. The two‐in‐one automatic registration technique can reduce the amount of time and intraoperative steps necessary to complete the registration process relative to the manual U‐shaped tube registration technique. Further follow‐up studies are necessary to expand on these results.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsSurgery, Computer-AssistedToothHumansDental Implantation, EndosseousRetrospective StudiesCone-Beam Computed TomographyComputer-Aided DesignImaging, Three-Dimensional

Stichwörter der Autor:innen

U-shaped tubeaccuracydynamic navigationimplant surgeryregistration methodregistration-and-fixationtwo-in-one

Substanzen

Dental Implants

Autor:innen und Institutionen

  • First Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomat…

ORCID-Profile: Bin-Zhang Wu

Förderung

  • Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology
  • School of Stomatology, Peking University

Zitieren

APA

Wu, B. Z., Xue, F., Ma, Y., & Sun, F. (2023). Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis. Clinical Oral Implants Research. https://doi.org/10.1111/clr.14034

Vancouver

Wu BZ, Xue F, Ma Y, Sun F. Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis. Clinical Oral Implants Research. 2023. doi:10.1111/clr.14034

BibTeX
@article{Wu2023,
  author = {Wu, Bin-Zhang and Xue, Fei and Ma, Yu and Sun, Feng},
  title = {Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis},
  journal = {Clinical Oral Implants Research},
  year = {2023},
  doi = {10.1111/clr.14034}
}
Kostenlos starten →