EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of Dental Implant Placement Using Dynamic Navigation With Different Optical Tracking Systems: An In Vitro Study

Yanjun Xiao, Zonghe Xu, Yanjun Lin, Wencan Ning, Qiyin Xu, Sihui Zhang, Jiang Chen iD, Dong Wu iD

Clinical Implant Dentistry and Related Research · 2025-12 · 27 (6)

DOI: 10.1111/cid.70102 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 26.11.2025. Verfasst von Yanjun Xiao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Key Laboratory of Oral Diseases and Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medica…. Hauptthemen laut MEDLINE: Dental Implantation, Endosseous, Surgery, Computer-Assisted, Dental Implants. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Fujian Provincial Health Technology Project, Undergraduate Education and Teaching Research Project, Fujian Medical University, Startup Fund for Scientific Research, Fujian Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

While dynamic navigation systems demonstrate superior precision in implant placement, the influence of variations in optical tracking technology on accuracy warrants further investigation.

Purpose

To compare the accuracy of dynamic navigation for implant placement using active infrared (AI), passive infrared (PI), and passive blue light (PB) optical tracking technologies. The null hypothesis is that there is no significant difference between the three alternative optical tracking technologies. Materials and Methods Three surgeons placed implants on 10 models using AI, PI, and PB optical tracking systems. Implants were placed on two sites per model (mandibular central incisors and mandibular first molar), with 180 implants assigned to be placed into 90 mandible models. The planned and placed implant positions were superimposed to assess procedural accuracy.

Results

The mean coronal, apical, and axial deviations for all implants were 0.82 ± 0.02 mm, 0.92 ± 0.02 mm, and 1.56° ± 0.06°, respectively. In the mandibular left central incisors, the coronal, apical, and axial deviations of the PB and AI groups and the PB and PI groups were significantly different ( p < 0.032, p < 0.001, p < 0.001, respectively, and both p < 0.001). In the mandibular left first molar, the coronal, apical, and axial deviations of the PB and PI groups were significantly different ( p < 0.001, p < 0.001, p = 0.003, respectively). The coronal and apical deviations of the PB and AI groups exhibited statistically significant differences (both p < 0.001).

Conclusions

The PB optical tracking system outperformed the AI and PI optical tracking systems regarding dynamic navigation accuracy, while the AI and PI optical tracking systems were comparable. All systems exhibit sufficient accuracy in vitro.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Implantation, EndosseousSurgery, Computer-AssistedDental ImplantsHumansMandibleIn Vitro TechniquesInfrared RaysOptical Imaging

Stichwörter der Autor:innen

accuracyactive infrared optical tracking systemdental implantdynamic navigationoptical tracking technologiespassive blue light optical tracking systempassive infrared optical tracking system

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Fujian Key Laboratory of Oral Diseases and Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, China.
  • School and Hospital of Stomatology, Fujian Medical University, Fuzhou, Fujian, China.
  • Fujian Provincial Engineering Research Center of Oral Biomaterial, Fujian Medical University, Fuzhou, Fujian, China.
  • Research Center of Dental and Craniofacial Implants, Fujian Medical University, Fuzhou, Fujian, China.

ORCID-Profile: Jiang Chen, Dong Wu

Förderung

  • Fujian Provincial Health Technology Project
  • Undergraduate Education and Teaching Research Project, Fujian Medical University
  • Startup Fund for Scientific Research, Fujian Medical University

Zitieren

APA

Xiao, Y., Xu, Z., Lin, Y., Ning, W., Xu, Q., Zhang, S., Chen, J., & Wu, D. (2025). Accuracy of Dental Implant Placement Using Dynamic Navigation With Different Optical Tracking Systems: An In Vitro Study. Clinical Implant Dentistry and Related Research, 27(6). https://doi.org/10.1111/cid.70102

Vancouver

Xiao Y, Xu Z, Lin Y, Ning W, Xu Q, Zhang S, et al. Accuracy of Dental Implant Placement Using Dynamic Navigation With Different Optical Tracking Systems: An In Vitro Study. Clinical Implant Dentistry and Related Research. 2025;27(6). doi:10.1111/cid.70102

BibTeX
@article{Xiao2025,
  author = {Xiao, Yanjun and Xu, Zonghe and Lin, Yanjun and Ning, Wencan and Xu, Qiyin and Zhang, Sihui and Chen, Jiang and Wu, Dong},
  title = {Accuracy of Dental Implant Placement Using Dynamic Navigation With Different Optical Tracking Systems: An In Vitro Study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2025},
  volume = {27},
  number = {6},
  doi = {10.1111/cid.70102}
}
Kostenlos starten →