EUVIMEDEUVIMED entdecken
Vergleichsstudie

Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches

Shuang Xi, Jun Hu, Guangna Yue, Shaohai Wang

The Journal of Prosthetic Dentistry · 2025-11 · 134 (5) · 1813-1819

DOI: 10.1016/j.prosdent.2024.07.032 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-11. Verfasst von Shuang Xi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China. Hauptthemen laut MEDLINE: Dental Implants, Robotic Surgical Procedures, Dental Implantation, Endosseous, Surgery, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Shanghai Pudong New Area Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Accurate placement of tilted implants is essential as they are typically close to important anatomic structures. Inaccurate implant position may damage those structures and affect outcomes. PURPOSE: The purpose of this in vitro study was to compare the accuracy and efficiency of an autonomous dental implant robotic (ADIR) system and a static computer-assisted implant surgery (sCAIS) system in placing tilted implants in edentulous patients. MATERIAL AND METHODS: Ten 3-dimensionally (3D) printed edentulous mandibular casts were assigned to 1 of 2 groups (ADIR and sCAIS). The coronal, apical, and angular deviations of the placement of tilted implants, preoperative preparation time, and surgical time were compared between the 2 groups. The paired samples t test and the independent samples t test were used to compare the groups (α=.05). RESULTS: The mean ±standard deviation of coronal, apical, and angular deviation in the ADIR group and sCAIS group were 0.47 ±0.06 mm versus 1.09 ±0.11 mm, 0.47 ±0.05 mm versus 1.53 ±0.14 mm, and 0.91 ±0.82 degrees versus 2.83 ±0.55 degrees, respectively. The deviations of the tilted implant positions in the ADIR were relatively small and significantly different from those of sCAIS (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsRobotic Surgical ProceduresDental Implantation, EndosseousSurgery, Computer-AssistedJaw, EdentulousHumansPrinting, Three-DimensionalIn Vitro TechniquesMandible

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Resident, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China.
  • Professor, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China. Electronic address: shaohaiwang@tongji.edu.cn.

Förderung

  • Shanghai Pudong New Area Health Commission

Zitieren

APA

Xi, S., Hu, J., Yue, G., & Wang, S. (2025). Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches. The Journal of Prosthetic Dentistry, 134(5), 1813-1819. https://doi.org/10.1016/j.prosdent.2024.07.032

Vancouver

Xi S, Hu J, Yue G, Wang S. Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches. The Journal of Prosthetic Dentistry. 2025;134(5):1813-1819. doi:10.1016/j.prosdent.2024.07.032

BibTeX
@article{Xi2025,
  author = {Xi, Shuang and Hu, Jun and Yue, Guangna and Wang, Shaohai},
  title = {Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  volume = {134},
  number = {5},
  pages = {1813--1819},
  doi = {10.1016/j.prosdent.2024.07.032}
}
Kostenlos starten →