Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches
The Journal of Prosthetic Dentistry · 2025-11 · 134 (5) · 1813-1819
DOI: 10.1016/j.prosdent.2024.07.032 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-11. Verfasst von Shuang Xi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Resident, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China. Hauptthemen laut MEDLINE: Dental Implants, Robotic Surgical Procedures, Dental Implantation, Endosseous, Surgery, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Shanghai Pudong New Area Health Commission.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Accurate placement of tilted implants is essential as they are typically close to important anatomic structures. Inaccurate implant position may damage those structures and affect outcomes. PURPOSE: The purpose of this in vitro study was to compare the accuracy and efficiency of an autonomous dental implant robotic (ADIR) system and a static computer-assisted implant surgery (sCAIS) system in placing tilted implants in edentulous patients. MATERIAL AND METHODS: Ten 3-dimensionally (3D) printed edentulous mandibular casts were assigned to 1 of 2 groups (ADIR and sCAIS). The coronal, apical, and angular deviations of the placement of tilted implants, preoperative preparation time, and surgical time were compared between the 2 groups. The paired samples t test and the independent samples t test were used to compare the groups (α=.05). RESULTS: The mean ±standard deviation of coronal, apical, and angular deviation in the ADIR group and sCAIS group were 0.47 ±0.06 mm versus 1.09 ±0.11 mm, 0.47 ±0.05 mm versus 1.53 ±0.14 mm, and 0.91 ±0.82 degrees versus 2.83 ±0.55 degrees, respectively. The deviations of the tilted implant positions in the ADIR were relatively small and significantly different from those of sCAIS (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Resident, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China.
- Professor, Department of Stomatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, PR China. Electronic address: shaohaiwang@tongji.edu.cn.
Förderung
- Shanghai Pudong New Area Health Commission
Zitieren
APA
Xi, S., Hu, J., Yue, G., & Wang, S. (2025). Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches. The Journal of Prosthetic Dentistry, 134(5), 1813-1819. https://doi.org/10.1016/j.prosdent.2024.07.032
Vancouver
Xi S, Hu J, Yue G, Wang S. Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches. The Journal of Prosthetic Dentistry. 2025;134(5):1813-1819. doi:10.1016/j.prosdent.2024.07.032
BibTeX
@article{Xi2025,
author = {Xi, Shuang and Hu, Jun and Yue, Guangna and Wang, Shaohai},
title = {Accuracy of an autonomous dental implant robotic system in placing tilted implants for edentulous arches},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
volume = {134},
number = {5},
pages = {1813--1819},
doi = {10.1016/j.prosdent.2024.07.032}
}
EUVIMED