Impact of Implant Mesiodistal Distance on Peri‐Implant Bone Loss: A Cross‐Sectional Retrospective Study
Clinical Implant Dentistry and Related Research · 2025
DOI: 10.1111/cid.13442 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, 2025. Verfasst von Wenwen Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Geriatric Dentistry, Peking University School and Hospital of Stomatology, Beijing, China. Hauptthemen laut MEDLINE: Alveolar Bone Loss, Dental Implants, Dental Implantation, Endosseous. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to verify the effect of our previously proposed mesiodistal distance for multiple posterior implants on preserving peri‐implant bone, and to provide a measurable criterion for predicting implant prognosis.
Methods
One hundred and two patients with dental implants placed in the posterior free‐end edentulous arches were recruited in this cross‐sectional study. Calibrated X‐rays (peri‐apical [PA] or bite‐wing x‐ray) were collected to measure the mesiodistal space as well as the corresponding bone resorption of implants after prosthesis placement. Implants were assigned to the test/control group according to whether their mesiodistal distance following our proposed algorithm. After adjusting covariates, logistic multivariate regression analyses were performed to examine the relationship between inter‐implant distance and marginal bone loss (MBL) during each follow‐up interval. The effect of smoking habits was also analyzed.
Results
Every observation period exhibited great significance between experimental and control group on peri‐implant bone level ( p = 0.006, 0.005, 0.001, 0.025, 0.001, correspondingly) and the difference had a tendency to grow as time went by except 4‐year (MD = −0.19, −0.39, −0.43, −0.30, −1.26, correspondingly). While no significant difference was observed between smokers and nonsmokers in the same group ( p > 0.05).
Conclusion
The mesiodistal algorithm of 4–4.6 mm (implant to adjacent canine tooth), 7–7.4 mm, 8–8.5 mm, and 9–9.5 mm was proved to be effective for maintaining peri‐implant bone level. It was also observed in our study that the impact of inter‐implant distance outweighed that of smoking. This study provided clinicians predictable prognostic outcomes for implants and reference for deciding treatment plans.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Geriatric Dentistry, Peking University School and Hospital of Stomatology, Beijing, China.
- Department of Periodontics and Oral Medicine, The University of Michigan School of Dentistry, Ann Arbor, Michigan, USA.
- The Department of Nosocial Infection Management, Peking University Third Hospital, Beijing, China.
ORCID-Profile: Wenwen Liu, Hom-Lay Wang
Zitieren
APA
Liu, W., Zhu, F., Han, L., Li, P., & Wang, H. L. (2025). Impact of Implant Mesiodistal Distance on Peri‐Implant Bone Loss: A Cross‐Sectional Retrospective Study. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/cid.13442
Vancouver
Liu W, Zhu F, Han L, Li P, Wang HL. Impact of Implant Mesiodistal Distance on Peri‐Implant Bone Loss: A Cross‐Sectional Retrospective Study. Clinical Implant Dentistry and Related Research. 2025. doi:10.1111/cid.13442
BibTeX
@article{Liu2025,
author = {Liu, Wenwen and Zhu, Fangyu and Han, Lu and Li, Pei and Wang, Hom-Lay},
title = {Impact of Implant Mesiodistal Distance on Peri‐Implant Bone Loss: A Cross‐Sectional Retrospective Study},
journal = {Clinical Implant Dentistry and Related Research},
year = {2025},
doi = {10.1111/cid.13442}
}
EUVIMED