Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants
Oral and Maxillofacial Surgery · 2024
DOI: 10.1007/s10006-024-01215-4 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Oral and Maxillofacial Surgery, 2024. Verfasst von Elisabeth Steyer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billro…. Hauptthemen laut MEDLINE: Dental Implants. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The aim of this retrospective study was to evaluate the outcomes of a two-piece implant system with a tube-in-tube internal connection after up to 15 years of clinical use. MATERIAL AND METHODS: A retrospective follow-up examination of patients treated with internal tube-in-tube implants between 2003 and 2006 was conducted. The implant survival rates, peri-implant conditions (marginal bone loss, bleeding on probing, plaque index, probing depth), and technical complications were determined. RESULTS: In total, 312 dental implants were placed in 152 patients. Of the original 152 patients enrolled, 245 implants in 112 patients were available for a follow-up evaluation after 11 to 15 years (mean observation time, 12.9 ± 1.1 years). The overall implant survival rate was 93.9%. Outcomes for MBL (1.49 ± 1.23 mm), PI (24.3 ± 22.2%), BOP (18.3 ± 28.7%), and PD (2.74 ± 1.21 mm) were observed. Selected parameters (time after implant surgery, smoking habits, bone augmentation (GBR)) showed an influence on MBL and PD. CONCLUSIONS: The internal tube-in-tube implant system showed favorable long-term results. The correlation of MBL and PD with the patient-specific factor smoking habit is in accordance with other studies. CLINICAL RELEVANCE: Camlog Root-Line implants with a tube-in-tube implant-abutment connection and a 1.6-mm polished neck configuration have demonstrated favorable long-term outcomes in daily clinical practice. However, it is important to note that these implants are no longer available on the market.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria.
- Division of Operative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, 8010, Graz, Austria. kerstin.theisen@medunigraz.at.
- Private Practice Straß, Graz, Austria.
Zitieren
APA
Steyer, E., Theisen, K., Hulla, H., Ubaidha Maheen, C., Sokolowski, A., & Lorenzoni, M. (2024). Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants. Oral and Maxillofacial Surgery. https://doi.org/10.1007/s10006-024-01215-4
Vancouver
Steyer E, Theisen K, Hulla H, Ubaidha Maheen C, Sokolowski A, Lorenzoni M. Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants. Oral and Maxillofacial Surgery. 2024. doi:10.1007/s10006-024-01215-4
BibTeX
@article{Steyer2024,
author = {Steyer, Elisabeth and Theisen, Kerstin and Hulla, Helfried and Ubaidha Maheen, Ceeneena and Sokolowski, Alwin and Lorenzoni, Martin},
title = {Eleven- to fifteen-year outcome for two-piece implants with an internal tube-in-tube connection: a cross-sectional analysis of 245 implants},
journal = {Oral and Maxillofacial Surgery},
year = {2024},
doi = {10.1007/s10006-024-01215-4}
}
EUVIMED