EUVIMEDEUVIMED entdecken
Crossref

Evaluation of surgical placement accuracy of customized CAD / CAM titanium mesh using screws‐position‐guided template: A retrospective comparative study

Dan Chen, Lingling Zheng, Chao Wang iD, Yuanding Huang iD, Haitao Huang, Antonio Apicella iD, Guiping Hu, Lizhen Wang, Yubo Fan

Clinical Implant Dentistry and Related Research · 2023-06 · 25 (3) · 519-531

DOI: 10.1111/cid.13205 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 14.04.2023. Verfasst von Dan Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Bi…. Hauptthemen laut MEDLINE: Dental Implants, Alveolar Ridge Augmentation. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Beijing, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Customized computer‐aided‐design/computer‐aided‐manufacturing (CAD/CAM) titanium meshes have been adopted for alveolar bone augmentation. But the inaccuracies between planned and created bone volume/contour are quite common, and the surgical placement of the customized mesh was considered as the first critical factor. However, the evaluation of surgical placement accuracy of customized mesh is currently lacking.

Purpose

The aim of this study was to evaluate the accuracy of the surgical placement of customized meshes.

Methods

A total of 30 cases, 20 without the screws‐position‐guided template and 10 with the screws‐position‐guided template, were included in this study. The cone beam CT (CBCT) data sets of pre‐ and postoperative were converted into 3D models and digitally aligned. Then the actual placement of customized mesh and retainer titanium screws was compared to the virtual one to assess the surgical placement accuracy of customized mesh. At least 6 months after surgery, a new CBCT was taken and converted into 3D models. Planned bone volume, created bone volume, vertical bone augmentation, healing complications rate, pseudo‐periosteum rate, exposure rate, and infection rate were all evaluated.

Results

The 3D digital reconstruction/registration analysis showed that the average difference between actual placement and planned one of customized mesh in positive and negative directions was 2.69 ± 0.70 mm and −1.41 ± 0.90 mm, respectively, without the screws‐position‐guided template. And the mean difference values between the actual and planned placement of the screws on the X and Y axes were 0.74 ± 0.85 mm and 0.89 ± 0.84 mm. In contrast, with the screws‐position‐guided template, the results were 2.38 ± 0.69 mm and −1.30 ± 1.13 mm. Accordingly, the mean difference values of screws were 0.76 ± 0.84 mm and 0.94 ± 0.72 mm. There was no statistical difference between the two groups, and the noninferiority of the control group compared to the test group was also confirmed by the comparative analysis.

Conclusion

It can be concluded that there is a certain deviation between the planned surgical placement and actual one of customized mesh, and using screws‐position‐guided template is of limited help for its accurate placement. Further research is needed to achieve precise surgical placement of the customized mesh to achieve precise alveolar bone augmentation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsAlveolar Ridge AugmentationDental Implantation, EndosseousTitaniumRetrospective StudiesSurgical MeshBone TransplantationMaxilla

Stichwörter der Autor:innen

3D reconstruction/registrationalveolar bone augmentationcustomized CAD/CAM titanium meshguided bone regenerationplacement accuracy

Substanzen

Dental ImplantsTitanium

Autor:innen und Institutionen

  • Key Laboratory of Biomechanics and Mechanobiology, Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, School of Engineering Medici…
  • Department of implantology, Stomatological Hospital of Chongqing Medical University, Chongqinig, China.
  • Department of Stomatology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
  • Advanced Materials Laboratory, Polytechnique School of Engineering and Base science, University of Campania, Aversa, Italy.

ORCID-Profile: Chao Wang, Yuanding Huang, Antonio Apicella

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Beijing
  • Fundamental Research Funds for the Central Universities
  • 111 Project
  • Higher Education Discipline Innovation Project

Zitieren

APA

Chen, D., Zheng, L., Wang, C., Huang, Y., Huang, H., Apicella, A., Hu, G., Wang, L., & Fan, Y. (2023). Evaluation of surgical placement accuracy of customized CAD / CAM titanium mesh using screws‐position‐guided template: A retrospective comparative study. Clinical Implant Dentistry and Related Research, 25(3), 519-531. https://doi.org/10.1111/cid.13205

Vancouver

Chen D, Zheng L, Wang C, Huang Y, Huang H, Apicella A, et al. Evaluation of surgical placement accuracy of customized CAD / CAM titanium mesh using screws‐position‐guided template: A retrospective comparative study. Clinical Implant Dentistry and Related Research. 2023;25(3):519-531. doi:10.1111/cid.13205

BibTeX
@article{Chen2023,
  author = {Chen, Dan and Zheng, Lingling and Wang, Chao and Huang, Yuanding and Huang, Haitao and Apicella, Antonio and Hu, Guiping and Wang, Lizhen and Fan, Yubo},
  title = {Evaluation of surgical placement accuracy of customized CAD / CAM titanium mesh using screws‐position‐guided template: A retrospective comparative study},
  journal = {Clinical Implant Dentistry and Related Research},
  year = {2023},
  volume = {25},
  number = {3},
  pages = {519--531},
  doi = {10.1111/cid.13205}
}
Kostenlos starten →