Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, online erschienen am 22.11.2026. Verfasst von Gareth D Mercer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Vision Sciences, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Société Canadienne d'Ophtalmologie.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

We evaluated a novel device and technique for performing suprachoroidal buckling and modelled the relationship between injection volume and buckle morphology. The device utilises a non‐sharp tissue separator which, via tangential blunt dissection, opens a channel to the suprachoroidal space (SCS).

Methods

We injected sodium hyaluronate 2.3% into the SCS of fresh whole human eyes ( n = 34), evaluating injection volumes of 0.1, 0.2 and 0.3 mL and needle insertion positions of 6, 10 and 15 mm posterior to the limbus, and measured the resulting buckle dimensions using B‐scan ultrasonography.

Results

All but one injection resulted in successful SCS buckle creation. We observed a linear relationship between injection volume and buckle height, transverse basal diameter (TBD) and longitudinal basal diameter (LBD; R 2 0.64, 0.65 and 0.64). A 0.1 mL injection resulted in a buckle with average height of 2.5 mm (95% confidence interval, CI: 2.3–2.8), TBD of 9.0 mm (95% CI: 8.5–9.5) and LBD of 8.6 mm (95% CI: 8.1–9.2). A 0.1 mL increase in volume was associated with an average height increase of 0.8 mm (95% CI: 0.6–1.0), TBD increase of 1.8 mm (95% CI: 1.3–2.2) and LBD increase of 1.6 mm (95% CI: 1.2–2.1). Needle insertion distance did not significantly modify these relationships.

Conclusions

This study establishes the technical feasibility of using a novel injector to perform minimally invasive SCS hydrogel buckling and provides estimates of expected buckle dimensions across a range of clinically relevant injection volumes.

Schlagwörter

Stichwörter der Autor:innen

suprachoroidal bucklingsuprachoroidal injectorviscopexyvisc‐buckle

Autor:innen und Institutionen

  • Department of Ophthalmology and Vision Sciences, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada.
  • John and Liz Tory Eye Centre, Sunnybrook Health Sciences Centre, Toronto, Canada.
  • Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel.
  • Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
  • Everads Therapy Ltd, Tel Aviv, Israel.

ORCID-Profile: Gareth D Mercer

Förderung

  • Société Canadienne d'Ophtalmologie

Zitieren

APA

Mercer, G. D., Barak, Y., Tamir, K. M., Kertes, P. J., & Eng, K. T. (2026). Preclinical Evaluation of a Novel Method and Device for Performing Minimally Invasive Suprachoroidal Hydrogel Buckling. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.70176

Vancouver

Mercer GD, Barak Y, Tamir KM, Kertes PJ, Eng KT. Preclinical Evaluation of a Novel Method and Device for Performing Minimally Invasive Suprachoroidal Hydrogel Buckling. Clinical & Experimental Ophthalmology. 2026. doi:10.1111/ceo.70176

BibTeX
@article{Mercer2026,
  author = {Mercer, Gareth D and Barak, Yoreh and Tamir, Keren Mano and Kertes, Peter J and Eng, Kenneth T},
  title = {Preclinical Evaluation of a Novel Method and Device for Performing Minimally Invasive Suprachoroidal Hydrogel Buckling},
  journal = {Clinical & Experimental Ophthalmology},
  year = {2026},
  doi = {10.1111/ceo.70176}
}
Kostenlos starten →