Magnetically guided microrobot via minimally invasive percutaneous cisternal access: a first preclinical evaluation
Journal of Neurosurgery · 01.10.2026 · 1-11
DOI: 10.3171/2026.4.jns252541 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neurosurgery, erschienen am 01.10.2026. Verfasst von Oana M Mereuta und 17 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Radiology, Mayo Clinic, Rochester, Minnesota. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE Magnetically guided microrobots could enable minimally invasive intracranial interventions by navigating CSF spaces without traversing brain parenchyma. However, clinical translation requires in vivo validation of delivery, control, retrieval, and short-term safety under realistic workflow conditions. The aim of this study was to assess the feasibility and initial safety of percutaneous cisterna magna access, microrobot navigation, and retrieval using an image-integrated electromagnetic coil platform in a large-animal model, targeting future application to Dandy-Walker malformation cyst fenestration. METHODS In this Good Laboratory Practice–compliant ovine study, 7 male sheep were allocated to an MRI-only control group (n = 1), flexion control group (n = 1), and treatment group (n = 3; percutaneous cisternal access, deployment of a 3.5 × 7–mm Parylene-C–coated bladed microrobot with a neodymium core, magnetic navigation, scripted dwell, and retrieval), with 2 animals designated as alternates. Preoperative MRI was used for planning, with intraoperative cone-beam CT fusion and biplanar fluoroscopy. The follow-up period was 28 days and included daily observation, weekly neurological examination, and analysis of hematology/chemistry, intraoperative CSF, and terminal necropsy with histopathology. Outcomes were descriptive. RESULTS The full workflow was completed in all 3 treated animals without conversion or rescue. Cannulation succeeded on the first attempt; continuous fluoroscopic visibility and stable magnetic control were maintained; and retrieval succeeded in a single maneuver. Postoperative recovery was uneventful, with weight gain and no neurological deficits over 28 days of follow-up. Laboratory values were within reference ranges except for 1 case of transient leukocytosis (day 0) that resolved. CSF was acellular/normal. Necropsy showed localized procedure-site changes only (dural fibrosis, thin adhesions in 2 of 3 treated animals). Histology revealed focal superficial vermian gliosis ≤ 2 mm in 2 of 3 treated animals without hemorrhage, necrosis, or off-target injury, and controls were within normal limits (1 case of minimal incidental axonal change in the flexion control). CONCLUSIONS Percutaneous cisternal delivery and retrieval of an untethered microrobot were feasible and tolerated in sheep, with localized tissue responses at 28 days. These findings support further studies focused on longer follow-up, workflow optimization, and disease-specific efficacy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 1Department of Radiology, Mayo Clinic, Rochester, Minnesota.
- 2Department of Neurointervention, Univ Brest LATIM INSERM UMR 1101, Brest, France.
- 3Department of Neurologic Surgery, Children's Hospital Orange County, Orange, California.
- 4Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota.
- 5Department of Neurosurgery, Faculty of Medicine of Juntendo University, Tokyo, Japan.
- 6Department of Research and Development, Bionaut Labs, Los Angeles, California; and.
Zitieren
APA
Mereuta, O. M., Ognard, J., Loudon, W. G., Bayraktar, E. A., Ueki, Y., Dai, D., Weissberg, J., Cho, S., Wang, E., Yuan, T., Vaghela, A., Ma, X., Lortscher, S., Montonye, D. R., Gow, C. K., Ahn, E. S., Brinjikji, W., & Kadirvel, R. (2026). Magnetically guided microrobot via minimally invasive percutaneous cisternal access: a first preclinical evaluation. Journal of Neurosurgery, 1-11. https://doi.org/10.3171/2026.4.jns252541
Vancouver
Mereuta OM, Ognard J, Loudon WG, Bayraktar EA, Ueki Y, Dai D, et al. Magnetically guided microrobot via minimally invasive percutaneous cisternal access: a first preclinical evaluation. Journal of Neurosurgery. 2026:1-11. doi:10.3171/2026.4.jns252541
BibTeX
@article{Mereuta2026,
author = {Mereuta, Oana M and Ognard, Julien and Loudon, William G and Bayraktar, Esref Alperen and Ueki, Yasuhito and Dai, Daying and Weissberg, Jack and Cho, Suehyun and Wang, Evaline and Yuan, Teresa and Vaghela, Anish and Ma, Xiaobo and Lortscher, Sarah and Montonye, Dan R and Gow, Christopher K and Ahn, Edward S and Brinjikji, Waleed and Kadirvel, Ramanathan},
title = {Magnetically guided microrobot via minimally invasive percutaneous cisternal access: a first preclinical evaluation},
journal = {Journal of Neurosurgery},
year = {2026},
pages = {1--11},
doi = {10.3171/2026.4.jns252541}
}
EUVIMED