High‐Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance

Marc G Sarossy, Sandy Rezk, Dongzhe Li, Xavier Hadoux, Maxime Jannaud, Michael A Coote, Ghee Soon Ang, Peter van Wijngaarden, Keith R Martin, Zhichao Wu iD

Clinical & Experimental Ophthalmology · 2025

DOI: 10.1111/ceo.14528 ↗

At a glance

Vergleichsstudie in Clinical & Experimental Ophthalmology, 2025. Written by Marc G Sarossy and 9 co-authors. Institution: Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. Major MEDLINE topics: Visual Field Tests, Visual Fields, Optic Nerve Diseases, Optic Disk. Cited 2 times so far (Crossref); 51 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: National Health & Medical Research Council of Australia, BrightFocus Foundation, F. Hoffmann-La Roche Ltd.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

To compare the performance of high‐resolution microperimetry testing against standard automated perimetry (SAP) for detecting glaucomatous damage seen on optical coherence tomography (OCT) scans.

Methods

250 eyes from 200 individuals underwent high‐resolution microperimetry testing of a hemifield using a stimulus pattern optimised to sample typical arcuate patterns of visual field loss in glaucoma. SAP was performed using a 24–2 stimulus pattern. The presence of glaucomatous damage in each hemifield was subsequently independently assessed by two graders based on a circumpapillary OCT circle scan, 6×6 mm optic disc‐centred OCT volume scan, and 15×15 mm widefield OCT volume scan.

Results

The hemifield‐based mean total deviation (MTD) and pointwise sensitivity standard deviation (PSD) for high‐resolution microperimetry and SAP were both independently associated with the presence of glaucomatous damage in multivariable logistic regression analyses ( p ≤ 0.046). Prediction models developed using these two parameters showed significantly higher performance with high‐resolution microperimetry compared to SAP (partial area under the receiver operating characteristic curve [pAUC] = 0.86 and 0.75 respectively; p = 0.007). The performance of microperimetry decreased with decreasing resolution when the MTD and PSD values were derived from every second, third, and sixth test locations (pAUC = 0.85 [ p = 0.16], 0.85 [ p = 0.044] and 0.84 [ p < 0.001] respectively), but they were all significantly better than SAP ( p ≤ 0.028 for all).

Conclusions

High‐resolution microperimetry enabled improved performance for detecting glaucomatous damage compared to SAP, highlighting the potential value of fundus‐tracking and higher‐resolution sampling for the detection of glaucomatous visual field loss.

Subjects

MeSH terms (MEDLINE)

Visual Field TestsVisual FieldsOptic Nerve DiseasesOptic DiskVision DisordersGlaucomaGlaucoma, Open-AngleHumansTomography, Optical CoherenceMaleFemaleProspective StudiesMiddle AgedAgedROC CurveIntraocular PressureSensitivity and SpecificityAdultRetinal Ganglion Cells

Author keywords

glaucomamicroperimetryoptical coherence tomographyvisual field tests

Authors and institutions

  • Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia.
  • Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Victoria, Australia.

ORCID profiles: Zhichao Wu

Funding

  • National Health & Medical Research Council of Australia
  • BrightFocus Foundation
  • F. Hoffmann-La Roche Ltd
  • Roche

Cite

APA

Sarossy, M. G., Rezk, S., Li, D., Hadoux, X., Jannaud, M., Coote, M. A., Ang, G. S., van Wijngaarden, P., Martin, K. R., & Wu, Z. (2025). High‐Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.14528

Vancouver

Sarossy MG, Rezk S, Li D, Hadoux X, Jannaud M, Coote MA, et al. High‐Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance. Clinical & Experimental Ophthalmology. 2025. doi:10.1111/ceo.14528

BibTeX
@article{Sarossy2025,
  author = {Sarossy, Marc G and Rezk, Sandy and Li, Dongzhe and Hadoux, Xavier and Jannaud, Maxime and Coote, Michael A and Ang, Ghee Soon and van Wijngaarden, Peter and Martin, Keith R and Wu, Zhichao},
  title = {High‐Resolution Microperimetry for Detecting Glaucomatous Damage: A Prospective Evaluation of Performance},
  journal = {Clinical & Experimental Ophthalmology},
  year = {2025},
  doi = {10.1111/ceo.14528}
}
Start for free →