Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer

Klemens Paul Kaiser iD, Tyll Jandewerth iD, Julian Bucur iD, Thomas Kohnen iD, Christoph Lwowski iD

Clinical & Experimental Ophthalmology · 2024

DOI: 10.1111/ceo.14418 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, 2024. Verfasst von Klemens Paul Kaiser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Axial Length, Eye, Biometry, Silicone Oils. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To assess changes in ocular biometry of the phakic eye after pars‐plana‐vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.

Methods

This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000‐centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept‐source optical coherence tomography‐based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.

Results

The mean age was 62.1 ± 8.3 years (range: 37–85). After PPV with SO fill, there was an increase in K mean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average ( p = 0.04). By adjusting the AL, the mean difference could be reduced to −0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.

Conclusions

While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceAxial Length, EyeBiometrySilicone OilsVitrectomyEndotamponadeRetinal DetachmentHumansRetrospective StudiesMiddle AgedMaleFemaleAgedAdultAged, 80 and overVisual AcuityAnterior ChamberRefraction, Ocular

Stichwörter der Autor:innen

IOL calculationbiometryendotamponaderetinal detachmentsilicon oil

Substanzen

Silicone Oils

Autor:innen und Institutionen

  • Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.

ORCID-Profile: Klemens Paul Kaiser, Tyll Jandewerth, Julian Bucur, Thomas Kohnen, Christoph Lwowski

Zitieren

APA

Kaiser, K. P., Jandewerth, T., Bucur, J., Kohnen, T., & Lwowski, C. (2024). Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/ceo.14418

Vancouver

Kaiser KP, Jandewerth T, Bucur J, Kohnen T, Lwowski C. Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer. Clinical & Experimental Ophthalmology. 2024. doi:10.1111/ceo.14418

BibTeX
@article{Kaiser2024,
  author = {Kaiser, Klemens Paul and Jandewerth, Tyll and Bucur, Julian and Kohnen, Thomas and Lwowski, Christoph},
  title = {Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer},
  journal = {Clinical & Experimental Ophthalmology},
  year = {2024},
  doi = {10.1111/ceo.14418}
}
Kostenlos starten →