EUVIMEDEUVIMED entdecken
Open Access

Optimizing axial length measurement success in advanced cataract patients through pupil dilation

Emmanuel Bettach, Hashem Totah, Yishay Weill, David Zadok, Adi Abulafia

Indian Journal of Ophthalmology · 2024

DOI: 10.4103/ijo.ijo_3316_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Emmanuel Bettach und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Shaare Zedek Medical Center, Affiliated to the Hebrew University, Jerusalem, Israel. Hauptthemen laut MEDLINE: Cataract, Tomography, Optical Coherence, Pupil, Biometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the impact of pharmacologic pupil dilation on axial length (AL) measurement in patients with dense cataracts and previous failed AL measurements carried out without pupil dilation.

Design

Retrospective case series.

Methods

All participants underwent swept-source optical coherence tomography (SS-OCT) biometry. Patients with unsuccessful AL measurements due to dense cataract underwent an additional SS-OCT biometric evaluation after pupil dilation, and the SS-OCT AL measurement was compared to the immersion ultrasound.

Results

The study included 3668 eyes of 3668 patients who underwent SS-OCT between October 2021 and March 2023. Of them, 102 eyes (2.8%) had failed AL measurements because of dense cataract. Eighty-seven of those 102 eyes underwent a repeat SS-OCT biometric exam following pharmacologic pupil dilation, after which AL measurements were successfully achieved in 27 (31.0%) of the 87 eyes. These measurements were found to be consistent with immersion ultrasound, supporting the validity of SS-OCT biometer measurements post dilation.

Conclusions

Pharmacologic pupil dilation improved the rate of successful SS-OCT biometrically measured AL in patients with failed AL measurement due to dense cataract.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CataractTomography, Optical CoherencePupilBiometryAxial Length, EyeMydriaticsHumansRetrospective StudiesMaleFemaleAgedMiddle AgedReproducibility of Results

Substanzen

Mydriatics

Autor:innen und Institutionen

  • Department of Ophthalmology, Shaare Zedek Medical Center, Affiliated to the Hebrew University, Jerusalem, Israel.

Zitieren

APA

Bettach, E., Totah, H., Weill, Y., Zadok, D., & Abulafia, A. (2024). Optimizing axial length measurement success in advanced cataract patients through pupil dilation. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_3316_23

Vancouver

Bettach E, Totah H, Weill Y, Zadok D, Abulafia A. Optimizing axial length measurement success in advanced cataract patients through pupil dilation. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_3316_23

BibTeX
@article{Bettach2024,
  author = {Bettach, Emmanuel and Totah, Hashem and Weill, Yishay and Zadok, David and Abulafia, Adi},
  title = {Optimizing axial length measurement success in advanced cataract patients through pupil dilation},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  doi = {10.4103/ijo.ijo_3316_23}
}
Kostenlos starten →