Fachartikel in der Zeitschrift Clinical & Experimental Ophthalmology, 2023-06. Verfasst von Veronika Röggla und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Lenses, Intraocular, Cataract, Phacoemulsification. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
We evaluated whether the best‐fit intraocular lens (IOL) power formula for the first operated eye (BF1) was also the most accurate formula for the second eye.
Methods
This was a retrospective study of 152 patients who underwent uncomplicated delayed bilateral cataract surgery with a minimum delay of 3 weeks using only one 1‐piece IOL (HOYA, Vivinex) at the Medical University of Vienna, Austria. Seven different formulae (Barrett Universal II, Castrop, Haigis, Hoffer Q, Holladay 1, Kane, and SRK/T) were investigated to test the formula selection approach with regard to the calculated mean and median absolute prediction errors (MAE/MedAE).
Results
The mean intraindividual difference in axial length was 0.2 mm (±0.3 mm). BF1 coincided with the best‐fit formula for the second eye (BF2) in 56% of patients ( p < 0.05). Using BF1 for the second eye led to a lower MedAE (0.22 dioptre, D) than using a formula at random (0.33 D) and was less accurate than using the best‐fit formula for each eye separately (0.1 D). The MedAEs of all formulae were generally low, ranging from 0.28 to 0.35 D.
Conclusion
Using BF1 for the second eye led to a lower MedAE than the random selection of a formula. Therefore, BF1 can be used for the second eye if the surgeon is unsure of the choice of formula.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology and Optometry, Medical University of Vienna, Vienna, Austria.
- Institut Für Experimentelle Ophthalmologie, Saarland University, Homburg, Germany.
- Department of Ophthalmology, Augen-und Laserklinik, Castrop-Rauxel, Germany.
ORCID-Profile: Veronika Röggla, Achim Langenbucher, Rupert Menapace
Zitieren
APA
Röggla, V., Langenbucher, A., Leydolt, C., Schartmüller, D., Schwarzenbacher, L., Hoffmann, P., & Menapace, R. (2023). Best fit formula approach in delayed sequential bilateral cataract surgery. Clinical & Experimental Ophthalmology, 51(6), 559-565. https://doi.org/10.1111/ceo.14261
Vancouver
Röggla V, Langenbucher A, Leydolt C, Schartmüller D, Schwarzenbacher L, Hoffmann P, et al. Best fit formula approach in delayed sequential bilateral cataract surgery. Clinical & Experimental Ophthalmology. 2023;51(6):559-565. doi:10.1111/ceo.14261
BibTeX
@article{Rggla2023,
author = {Röggla, Veronika and Langenbucher, Achim and Leydolt, Christina and Schartmüller, Daniel and Schwarzenbacher, Luca and Hoffmann, Peter and Menapace, Rupert},
title = {Best fit formula approach in delayed sequential bilateral cataract surgery},
journal = {Clinical & Experimental Ophthalmology},
year = {2023},
volume = {51},
number = {6},
pages = {559--565},
doi = {10.1111/ceo.14261}
}
EUVIMED