Accuracy of twelve intraocular lens calculation formulas in highly myopic eyes
International Ophthalmology · 2026
DOI: 10.1007/s10792-026-04016-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, 2026. Verfasst von Guang-Yue Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 10…. Hauptthemen laut MEDLINE: Lenses, Intraocular, Biometry, Refraction, Ocular, Optics and Photonics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The Excellent Clinical Research Program for Research Wards.
Abstract (Originalsprache)
PURPOSE: To investigate the accuracy, stability, and influencing factors of 12 intraocular lens (IOL) calculation formulas in highly myopic cataract patients. METHODS: Retrospective Case Series. Clinical data were collected from highly myopic cataract patients who underwent cataract extraction surgery at Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, between January 2024 and January 2025. Patients were stratified into subgroups based on axial length, keratometry, anterior chamber depth and axial length to corneal radius ratio (AL/r). The prediction error (PE), absolute error (AE), root-mean-square absolute prediction error (RMSAE) and the percentage of eyes with an absolute error within ± 0.25 D, ± 0.50 D, ± 0.75 D, and ± 1.00 D were recorded and compared for the following 12 IOL formulas: Barrett Universal II, Cooke K6, Castrop, Kane, EVO 2.0, Pearl-DGS, Hoffer QST, SRK-T, Haigis, Holladay 1, Holladay 2, and Hoffer Q. Statistical analysis was performed using Analysis of Variance (ANOVA), Friedman test, Kruskal-Wallis test, Dunn's test, and Cochran Q test. RESULTS: A total of 255 patients (255 eyes) were included in this study, comprising 113 males and 142 females, with a mean age of 57.8 ± 9.9 years. The difference in absolute errors among the 12 IOL formulas was statistically significant (χ2 = 327.59, P 0.05). CONCLUSION: For highly myopic cataract patients, modern IOL formulas demonstrated superior accuracy compared to traditional formulas. The accuracy was predominantly influenced by axial length, with keratometry and anterior chamber depth playing minor roles. The Hoffer QST and Pearl-DGS formulas, in particular, showed consistent and stable performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
- Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. wanxh@ccmu.edu.cn.
- Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China. jszhang@ccmu.edu.cn.
Förderung
- The Excellent Clinical Research Program for Research Wards
Zitieren
APA
Li, G. Y., Li, Z. Y., Yang, Z. H., Zhao, P., Li, M., Xu, J., Wan, X. H., & Zhang, J. S. (2026). Accuracy of twelve intraocular lens calculation formulas in highly myopic eyes. International Ophthalmology. https://doi.org/10.1007/s10792-026-04016-8
Vancouver
Li GY, Li ZY, Yang ZH, Zhao P, Li M, Xu J, et al. Accuracy of twelve intraocular lens calculation formulas in highly myopic eyes. International Ophthalmology. 2026. doi:10.1007/s10792-026-04016-8
BibTeX
@article{Li2026,
author = {Li, Guang-Yue and Li, Zhong-Yan and Yang, Zhao-Heng and Zhao, Peng and Li, Meng and Xu, Jie and Wan, Xiu-Hua and Zhang, Jing-Shang},
title = {Accuracy of twelve intraocular lens calculation formulas in highly myopic eyes},
journal = {International Ophthalmology},
year = {2026},
doi = {10.1007/s10792-026-04016-8}
}
EUVIMED