EUVIMEDObjevte EUVIMED
Crossref

A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US

Laura Berton Eidt iD, Cáren Nunes de Oliveira, Yago Borges Biz De Lagos, Geise Lilian Menezes Solera, Rogério Izquierdo, Erika Laurini de Souza Meyer, Vanessa Suñé Mattevi, Lenara Golbert iD

Clinical Endocrinology · 2023-03 · 98 (3) · 415-425

DOI: 10.1111/cen.14799 ↗

At a glance

Journal article in Clinical Endocrinology, published online on 2022-08-03. Written by Laura Berton Eidt and 7 co-authors. Institution: Endocrine Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil. Major MEDLINE topics: Thyroid Nodule, Thyroid Neoplasms. Cited 18 times so far (Crossref); 35 references. Funded by: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Objective

Prospective data on the accuracy of ultrasound (US) classification systems in thyroid nodules are still scarce. The aim of this study is to compare the accuracy of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR‐TIRADS) and European (EU)‐TIRADS classification systems. Design and Patients Consecutive patients with one or more thyroid nodule(s) who underwent fine‐needle aspiration (FNA) under ultrasonographic guidance (FNA‐US) were prospectively evaluated.

Measurements

Clinical evaluation and US data were collected. The reference standard used for this study was FNA‐US cytology and histopathological diagnosis.

Results

A total of 186 thyroid nodules in 166 patients were evaluated, resulting in 168 nodules from 149 patients with conclusive benign or malignant results. Sensitivity, specificity, negative predictive value (NPV) and false negative (FN) were 100.0%, 28.7%, 100.0% and 0.0%, respectively, for ACR‐TIRADS; and 90.0%, 19.1%, 96.8% and 9.1% ( n = 1), respectively, for EU‐TIRADS. The number of unnecessary FNA‐US indicated by ACR‐TIRADS was lower than EU‐TIRADS (71.3% vs. 80.9%, p = .017), and the number of possibly avoided FNA‐US was higher (26.7% vs. 17.8%). Using the same threshold of ACR‐TIRADS to indicate FNA‐US in EU‐TIRADS 3 nodules (2.5 cm), there was an improvement in specificity (30.6%) and avoided FNA‐US (28.6%). The best performance of both systems was demonstrated when FNA‐US would be indicated only in highly suspicious nodules and/or in the presence of lymphadenopathy, with 85.7% and 89.3% of possibly avoided FNA‐US for ACR‐TIRADS and EU‐TIRADS, respectively, without increasing FN.

Conclusion

Both systems presented high sensitivity, but low specificity in selecting nodules for FNA‐US. The use of nodular size for FNA‐US selection is questioned.

Subjects

MeSH terms (MEDLINE)

Thyroid NoduleThyroid NeoplasmsHumansBiopsy, Fine-NeedleRetrospective StudiesUltrasonography

Author keywords

fine needle biopsythyroid cancerthyroid imaging reporting and data systemthyroid noduleultrasonography

Authors and institutions

  • Endocrine Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
  • Universidade Federal de Ciências da Saúde de Porto Alegre-UFCSPA, Porto Alegre, Rio Grande do Sul, Brazil.
  • Radiology Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
  • Internal Medicine Department, Universidade Federal de Ciências da Saúde de Porto Alegre-UFCSPA, Porto Alegre, Rio Grande do Sul, Brazil.

ORCID profiles: Laura Berton Eidt, Lenara Golbert

Funding

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul

Cite

APA

Eidt, L. B., Nunes de Oliveira, C., Lagos, Y. B. B., Solera, G. L. M., Izquierdo, R., Meyer, E. L. S., Mattevi, V. S., & Golbert, L. (2023). A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US. Clinical Endocrinology, 98(3), 415-425. https://doi.org/10.1111/cen.14799

Vancouver

Eidt LB, Nunes de Oliveira C, Lagos YBB, Solera GLM, Izquierdo R, Meyer ELS, et al. A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US. Clinical Endocrinology. 2023;98(3):415-425. doi:10.1111/cen.14799

BibTeX
@article{Eidt2023,
  author = {Eidt, Laura Berton and Nunes de Oliveira, Cáren and Lagos, Yago Borges Biz De and Solera, Geise Lilian Menezes and Izquierdo, Rogério and Meyer, Erika Laurini de Souza and Mattevi, Vanessa Suñé and Golbert, Lenara},
  title = {A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US},
  journal = {Clinical Endocrinology},
  year = {2023},
  volume = {98},
  number = {3},
  pages = {415--425},
  doi = {10.1111/cen.14799}
}