A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US
Clinical Endocrinology · 2023-03 · 98 (3) · 415-425
DOI: 10.1111/cen.14799 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Endocrinology, online erschienen am 03.08.2022. Verfasst von Laura Berton Eidt und 7 weiteren Autor:innen. Beteiligte Einrichtung: Endocrine Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil. Hauptthemen laut MEDLINE: Thyroid Nodule, Thyroid Neoplasms. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul.
Abstract (Originalsprache)
Objective
Prospective data on the accuracy of ultrasound (US) classification systems in thyroid nodules are still scarce. The aim of this study is to compare the accuracy of the American College of Radiology Thyroid Imaging Reporting and Data System (ACR‐TIRADS) and European (EU)‐TIRADS classification systems. Design and Patients Consecutive patients with one or more thyroid nodule(s) who underwent fine‐needle aspiration (FNA) under ultrasonographic guidance (FNA‐US) were prospectively evaluated.
Measurements
Clinical evaluation and US data were collected. The reference standard used for this study was FNA‐US cytology and histopathological diagnosis.
Results
A total of 186 thyroid nodules in 166 patients were evaluated, resulting in 168 nodules from 149 patients with conclusive benign or malignant results. Sensitivity, specificity, negative predictive value (NPV) and false negative (FN) were 100.0%, 28.7%, 100.0% and 0.0%, respectively, for ACR‐TIRADS; and 90.0%, 19.1%, 96.8% and 9.1% ( n = 1), respectively, for EU‐TIRADS. The number of unnecessary FNA‐US indicated by ACR‐TIRADS was lower than EU‐TIRADS (71.3% vs. 80.9%, p = .017), and the number of possibly avoided FNA‐US was higher (26.7% vs. 17.8%). Using the same threshold of ACR‐TIRADS to indicate FNA‐US in EU‐TIRADS 3 nodules (2.5 cm), there was an improvement in specificity (30.6%) and avoided FNA‐US (28.6%). The best performance of both systems was demonstrated when FNA‐US would be indicated only in highly suspicious nodules and/or in the presence of lymphadenopathy, with 85.7% and 89.3% of possibly avoided FNA‐US for ACR‐TIRADS and EU‐TIRADS, respectively, without increasing FN.
Conclusion
Both systems presented high sensitivity, but low specificity in selecting nodules for FNA‐US. The use of nodular size for FNA‐US selection is questioned.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Endocrine Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
- Universidade Federal de Ciências da Saúde de Porto Alegre-UFCSPA, Porto Alegre, Rio Grande do Sul, Brazil.
- Radiology Division, Irmandade da Santa Casa de Misericórdia de Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil.
- Internal Medicine Department, Universidade Federal de Ciências da Saúde de Porto Alegre-UFCSPA, Porto Alegre, Rio Grande do Sul, Brazil.
ORCID-Profile: Laura Berton Eidt, Lenara Golbert
Förderung
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul
Zitieren
APA
Eidt, L. B., Nunes de Oliveira, C., Lagos, Y. B. B., Solera, G. L. M., Izquierdo, R., Meyer, E. L. S., Mattevi, V. S., & Golbert, L. (2023). A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US. Clinical Endocrinology, 98(3), 415-425. https://doi.org/10.1111/cen.14799
Vancouver
Eidt LB, Nunes de Oliveira C, Lagos YBB, Solera GLM, Izquierdo R, Meyer ELS, et al. A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US. Clinical Endocrinology. 2023;98(3):415-425. doi:10.1111/cen.14799
BibTeX
@article{Eidt2023,
author = {Eidt, Laura Berton and Nunes de Oliveira, Cáren and Lagos, Yago Borges Biz De and Solera, Geise Lilian Menezes and Izquierdo, Rogério and Meyer, Erika Laurini de Souza and Mattevi, Vanessa Suñé and Golbert, Lenara},
title = {A prospective comparison of ACR‐TIRADS and EU‐TIRADS in thyroid nodule assessment for FNA‐US},
journal = {Clinical Endocrinology},
year = {2023},
volume = {98},
number = {3},
pages = {415--425},
doi = {10.1111/cen.14799}
}
EUVIMED