Ergonomic and Workload Challenges in Minimally Invasive Liver Surgery: A Comparative Pilot Study of Robotic and Laparoscopic Approaches
Asian Journal of Endoscopic Surgery · 2026-01 · 19 (1)
DOI: 10.1111/ases.70399 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Asian Journal of Endoscopic Surgery, online erschienen am 16.11.2026. Verfasst von Rodrigo Antonio Gasque und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Treatment of Hepatobiliary and Pancreatic Diseases, Ageo Central General Hospital, Saitama, Japan. Hauptthemen laut MEDLINE: Laparoscopy, Ergonomics, Workload, Robotic Surgical Procedures. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Introduction
Minimally invasive liver resections (MILR), including laparoscopic and robotic‐assisted approaches, provide patient benefits such as reduced tissue trauma and faster recovery but may impose substantial physical and cognitive demands on surgeons. Although robotic‐assisted surgery may improve ergonomics, comparative evidence remains limited. This pilot study compared ergonomic risk, workload, and discomfort between laparoscopic and robotic‐assisted liver resections.
Methods
This prospective, single‐center, non‐randomized pilot study was conducted at Ageo Central General Hospital, Japan, between October 2024 and February 2025. Three surgeons performed 15 MILR, including 9 robotic‐assisted and 6 laparoscopic procedures. Ergonomic risk was assessed using the Rapid Entire Body Assessment (REBA), and workload was measured with the SURG‐TLX questionnaire. Pre‐ and postoperative body part discomfort was also recorded. Statistical analyses included Mann–Whitney U , Wilcoxon signed‐rank, and Spearman correlation tests.
Results
Laparoscopic procedures showed significantly higher ergonomic risk than robotic‐assisted procedures, with median REBA scores of 10 (IQR 10–10) versus 4 (IQR 4–5), respectively ( p = 0.0012). Mean SURG‐TLX scores were also significantly higher in the laparoscopic group (88.33 ± 13.08 vs. 41.22 ± 17.39, p = 0.0015). Mental demand, situational stress, temporal demand, and distractions were greater during laparoscopic surgery (all p < 0.05). Postoperative discomfort was higher after laparoscopic cases (median 18.5 vs. 11.0, p = 0.038).
Conclusion
In this exploratory pilot study, robotic‐assisted liver resection was associated with lower ergonomic risk, perceived workload, and surgeon discomfort than laparoscopic liver resection. These findings should be interpreted cautiously given the small sample size and potential confounding factors and should be considered hypothesis‐generating. Larger multicenter studies are needed to confirm these observations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Advanced Treatment of Hepatobiliary and Pancreatic Diseases, Ageo Central General Hospital, Saitama, Japan.
ORCID-Profile: Rodrigo Antonio Gasque, Taiga Wakabayashi, Jonathan Seak Chen Ken, Yusuke Nie, Go Wakabayashi
Zitieren
APA
Gasque, R. A., Wakabayashi, T., Chen Ken, J. S., Teshigahara, Y., Nie, Y., & Wakabayashi, G. (2026). Ergonomic and Workload Challenges in Minimally Invasive Liver Surgery: A Comparative Pilot Study of Robotic and Laparoscopic Approaches. Asian Journal of Endoscopic Surgery, 19(1). https://doi.org/10.1111/ases.70399
Vancouver
Gasque RA, Wakabayashi T, Chen Ken JS, Teshigahara Y, Nie Y, Wakabayashi G. Ergonomic and Workload Challenges in Minimally Invasive Liver Surgery: A Comparative Pilot Study of Robotic and Laparoscopic Approaches. Asian Journal of Endoscopic Surgery. 2026;19(1). doi:10.1111/ases.70399
BibTeX
@article{Gasque2026,
author = {Gasque, Rodrigo Antonio and Wakabayashi, Taiga and Chen Ken, Jonathan Seak and Teshigahara, Yu and Nie, Yusuke and Wakabayashi, Go},
title = {Ergonomic and Workload Challenges in Minimally Invasive Liver Surgery: A Comparative Pilot Study of Robotic and Laparoscopic Approaches},
journal = {Asian Journal of Endoscopic Surgery},
year = {2026},
volume = {19},
number = {1},
doi = {10.1111/ases.70399}
}
EUVIMED