Robotic intracorporeal anastomosis enhances technical precision while reducing surgeon cognitive load: a prospective multicentre study
Surgical Endoscopy · 2026
DOI: 10.1007/s00464-026-13095-8 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Surgical Endoscopy, 2026. Verfasst von Yit J Leang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, School of Translational Medicine, Alfred Centre, Monash University, Level 699 Commercial Road, Melbourne, VIC, 3004, Australia…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Laparoscopy, Clinical Competence, Gastric Bypass. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Training Program, Monash University.
Abstract (Originalsprache)
Background
Robotic surgical platforms offer enhanced dexterity and ergonomics, yet their impact on technical precision and surgeon cognitive workload (CWL) remains ill-defined. This study compared robotic versus laparoscopic gastrojejunal (GJ) anastomosis during gastric bypass to determine differences in technical precision and CWL.
Methods
A prospective multicentre observational study was conducted across eight tertiary centres. Experienced bariatric surgeons beyond their learning curves performed standardised GJ anastomoses using either robotic or laparoscopic platforms. Objective performance was assessed using validated tools (BOSATS, GOALS and GEARS), and six predefined precision metrics. Surgeon CWL was measured using the NASA Task Load Index (NASA-TLX). Data were analysed using a nested mixed-effects model to control for inter-surgeon variance, with subgroup stratification by case complexity.
Results
A total of 109 cases were analysed (66 laparoscopic, 43 robotic). Global objective performance scores were comparable between groups (laparoscopic 4.51 vs. robotic 4.58; p = 0.48). Nested analysis accounting for high inter-surgeon variance demonstrated that robotic assistance significantly reduced surgeon frustration ( p = 0.03). Subgroup analysis revealed that the robotic platform significantly reduced overall NASA-TLX scores in both primary ( p = 0.001) and complex revisional cases ( p < 0.0001). Task-specific precision favoured the robotic approach in primary cases, with fewer incorrect suture placements ( p = 0.03) and missed knot throws ( p = 0.004). Notably, the significant inverse correlation between CWL and performance observed in laparoscopy ( r = − 0.487, p = 0.001) was completely neutralized in the robotic cohort ( r = − 0.009, p = 0.96).
Conclusion
Robotic GJ anastomosis is associated with enhanced task-specific precision and a clinically meaningful reduction in CWL, particularly during complex revisional procedures. By decoupling surgeon stress from technical fidelity, the robotic platform acts as a performance stabilizer during demanding reconstructive tasks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, School of Translational Medicine, Alfred Centre, Monash University, Level 699 Commercial Road, Melbourne, VIC, 3004, Australia. yit.leang@monash.edu.
- Department of Oesophago-Gastric and Bariatric Surgery, Alfred Hospital, Melbourne, VIC, Australia. yit.leang@monash.edu.
- Department of Surgery, School of Translational Medicine, Alfred Centre, Monash University, Level 699 Commercial Road, Melbourne, VIC, 3004, Australia.
- Department of Oesophago-Gastric and Bariatric Surgery, Alfred Hospital, Melbourne, VIC, Australia.
Förderung
- Australian Research Training Program
- Monash University
Zitieren
APA
Leang, Y. J., Lourensz, K. R., Vanguardia, M. K., Hensman, C. S., Loh, D., Chen, R., Packiyanathan, A. J., Kong, J. C. H., Australian Robotic Bariatric Interest Group (ARBIG), Brown, W. A., & Burton, P. R. (2026). Robotic intracorporeal anastomosis enhances technical precision while reducing surgeon cognitive load: a prospective multicentre study. Surgical Endoscopy. https://doi.org/10.1007/s00464-026-13095-8
Vancouver
Leang YJ, Lourensz KR, Vanguardia MK, Hensman CS, Loh D, Chen R, et al. Robotic intracorporeal anastomosis enhances technical precision while reducing surgeon cognitive load: a prospective multicentre study. Surgical Endoscopy. 2026. doi:10.1007/s00464-026-13095-8
BibTeX
@article{Leang2026,
author = {Leang, Yit J and Lourensz, Kaleb R and Vanguardia, Maria K and Hensman, Chrys S and Loh, Damien and Chen, Richard and Packiyanathan, Andrew J and Kong, Joseph C H and Australian Robotic Bariatric Interest Group (ARBIG), Australian Robotic Bariatric Interest Group (ARBIG) and Brown, Wendy A and Burton, Paul R},
title = {Robotic intracorporeal anastomosis enhances technical precision while reducing surgeon cognitive load: a prospective multicentre study},
journal = {Surgical Endoscopy},
year = {2026},
doi = {10.1007/s00464-026-13095-8}
}
EUVIMED