EUVIMEDOpdag EUVIMED
Crossref

A Novel Liver Retraction Method Using a Polypropylene Suture in Robotic Gastrectomy for Gastric Cancer: The Subphrenic Pulley Method

Masashi Negita iD, Kazunari Misawa iD, Yuichi Ito, Seiji Ito, Tetsuya Abe iD, Koji Komori, Yasuhiro Shimizu

Asian Journal of Endoscopic Surgery · 2025

DOI: 10.1111/ases.70047 ↗

At a glance

Journal article in Asian Journal of Endoscopic Surgery, 2025. Written by Masashi Negita and 6 co-authors. Institution: Department of Gastroenterological Surgery, Aichi Cancer Center Hospital, Nagoya, Japan. Major MEDLINE topics: Gastrectomy, Stomach Neoplasms, Robotic Surgical Procedures, Suture Techniques. 28 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Effective liver retraction is crucial in minimally invasive upper gastrointestinal surgeries, including laparoscopic gastrectomy and robotic gastrectomy (RG) for gastric cancer, to ensure optimal visualization and sufficient working space. Various techniques have been developed to improve the surgical view, simplify procedures, and reduce complications. However, liver enzyme elevation has been a notable concern in these procedures. To address these challenges, we developed the subphrenic pulley (SP) method, a novel liver retraction technique, and evaluated its safety and feasibility in RG.

Methods

We retrospectively analyzed the initial 111 consecutive cases of RG for gastric cancer at a single center between January 2016 and September 2023. The SP method used a 2‐0 polypropylene suture with a curved needle, which was placed in the left subphrenic peritoneum, the right side of the esophageal hiatus, and the right subphrenic peritoneum. The suture ends were pulled out from the left upper abdominal wall, achieving ventral and cranial retractions of both the lateral segment and round ligament of the liver.

Results

No case required re‐retraction or additional methods, and no case of liver laceration was observed. The incidence of Grade ≥ 3 liver enzyme elevation was 12.6% (14/111) in all cases and 3.5% (3/86) in the subset of cases without aberrant left hepatic artery dissection. Additionally, no patient needed treatment for liver dysfunction.

Conclusion

The SP method is a valuable, simple, and safe liver retraction technique in minimally invasive upper gastrointestinal surgeries, ensuring effective retraction without requiring additional skin incisions.

Subjects

MeSH terms (MEDLINE)

GastrectomyStomach NeoplasmsRobotic Surgical ProceduresSuture TechniquesSuturesLiverHumansMaleRetrospective StudiesFemaleMiddle AgedAgedPolypropylenesFeasibility StudiesAdultAged, 80 and over

Author keywords

polypropylene suturesrobotic gastrectomysurgical techniques

Substances

Polypropylenes

Authors and institutions

  • Department of Gastroenterological Surgery, Aichi Cancer Center Hospital, Nagoya, Japan.

ORCID profiles: Masashi Negita, Kazunari Misawa, Tetsuya Abe

Cite

APA

Negita, M., Misawa, K., Ito, Y., Ito, S., Abe, T., Komori, K., & Shimizu, Y. (2025). A Novel Liver Retraction Method Using a Polypropylene Suture in Robotic Gastrectomy for Gastric Cancer: The Subphrenic Pulley Method. Asian Journal of Endoscopic Surgery. https://doi.org/10.1111/ases.70047

Vancouver

Negita M, Misawa K, Ito Y, Ito S, Abe T, Komori K, et al. A Novel Liver Retraction Method Using a Polypropylene Suture in Robotic Gastrectomy for Gastric Cancer: The Subphrenic Pulley Method. Asian Journal of Endoscopic Surgery. 2025. doi:10.1111/ases.70047

BibTeX
@article{Negita2025,
  author = {Negita, Masashi and Misawa, Kazunari and Ito, Yuichi and Ito, Seiji and Abe, Tetsuya and Komori, Koji and Shimizu, Yasuhiro},
  title = {A Novel Liver Retraction Method Using a Polypropylene Suture in Robotic Gastrectomy for Gastric Cancer: The Subphrenic Pulley Method},
  journal = {Asian Journal of Endoscopic Surgery},
  year = {2025},
  doi = {10.1111/ases.70047}
}
Start for free →