Development and validation of a high‐quality simulator with exchangeable peritoneum for transabdominal preperitoneal laparoscopic inguinal hernia repair
Asian Journal of Endoscopic Surgery · 2024
DOI: 10.1111/ases.13362 ↗At a glance
Validierungsstudie in Asian Journal of Endoscopic Surgery, 2024. Written by Ayako Shibuya and 5 co-authors. Institution: Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan. Major MEDLINE topics: Hernia, Inguinal, Laparoscopy, Herniorrhaphy, Peritoneum. Cited 2 times so far (Crossref); 27 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Introduction
Practical simulation training with proper haptic feedback and the fragility of the human body is required to overcome the long learning curve associated with laparoscopic inguinal hernia repair (LIHR). However, few hernia models accurately reflect the texture and fragility of the human body. Therefore, in this study, we developed a novel model for transabdominal preperitoneal (TAPP) LIHR training and evaluated its validity.
Methods
We developed a high‐quality mock peritoneum with a hydrated polyvinyl alcohol layer and a unique two‐way crossing cellulose fiber layer. To complete the simulation, the peritoneum was adhered to a urethane foam inguinal base with surgical landmarks. Participants could perform all the procedures required for the TAPP LIHR. Twenty‐four surgeons performed TAPP LIHR simulation using a novel simulator. Their opinions were rated on a 5‐point Likert scale. Additionally, 6 surgical residents and 10 surgical experts performed the procedure. Their performance was evaluated using the TAPP checklist score and procedure time.
Results
Most participants strongly agreed that the TAPP LIHR simulator with an exchangeable peritoneum model was useful. The participants agreed on the model fidelity for tactile sensation, forceps handling, and humanlike anatomy. In comparisons between surgical residents and experts, the experts had significantly higher scores (10.6 vs. 17.2, p < 0.05) and shorter procedure times (92.3 vs. 55.9 min; p < .05) than did surgical residents.
Conclusions
We developed a high‐quality exchangeable peritoneal model that mimics the human peritoneum's texture and fragility. This model enhances laparoscopic simulation training, potentially shortening TAPP LIHR learning curves.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Surgical Oncology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
- Department of Surgery, National Hospital Organization (NHO) Tokyo Medical Center, Tokyo, Japan.
- Research Center for Clinical Medicine, International University of Health and Welfare, Tokyo, Japan.
- Department of Surgery, Sassa General Hospital, Tokyo, Japan.
ORCID profiles: Yoh Isobe, Yuichi Nishihara
Cite
APA
Shibuya, A., Isobe, Y., Nishihara, Y., Matsumoto, S., Nagayasu, T., & Matsumoto, K. (2024). Development and validation of a high‐quality simulator with exchangeable peritoneum for transabdominal preperitoneal laparoscopic inguinal hernia repair. Asian Journal of Endoscopic Surgery. https://doi.org/10.1111/ases.13362
Vancouver
Shibuya A, Isobe Y, Nishihara Y, Matsumoto S, Nagayasu T, Matsumoto K. Development and validation of a high‐quality simulator with exchangeable peritoneum for transabdominal preperitoneal laparoscopic inguinal hernia repair. Asian Journal of Endoscopic Surgery. 2024. doi:10.1111/ases.13362
BibTeX
@article{Shibuya2024,
author = {Shibuya, Ayako and Isobe, Yoh and Nishihara, Yuichi and Matsumoto, Sumio and Nagayasu, Takeshi and Matsumoto, Keitaro},
title = {Development and validation of a high‐quality simulator with exchangeable peritoneum for transabdominal preperitoneal laparoscopic inguinal hernia repair},
journal = {Asian Journal of Endoscopic Surgery},
year = {2024},
doi = {10.1111/ases.13362}
}
EUVIMED