Systematic scoping review: Use of the faecal immunochemical test residual buffer to enhance colorectal cancer screening
Alimentary Pharmacology & Therapeutics · 2024
DOI: 10.1111/apt.17947 ↗At a glance
Scoping Review in Alimentary Pharmacology & Therapeutics, 2024. Written by Timothy McAuliffe and 3 co-authors. Institution: Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA. Major MEDLINE topics: Colorectal Neoplasms, MicroRNAs. 61 references. Funded by: Department of Veterans Affairs Medical Center, White River Junction, VT.
Abstract (original language)
Background
The faecal immunochemical test (FIT) is an inexpensive and convenient modality to screen for colorectal cancer. However, its one‐time sensitivity for detecting colorectal cancer and cancer precursors is limited. There is growing interest in using the non‐haemoglobin contents of FIT residual buffer to enhance colonic neoplasia detection.
Aim
To establish from the literature a framework to catalogue candidate biomarkers within FIT residual buffer for non‐invasive colorectal cancer screening.
Methods
The search strategy evaluated PubMed, Scopus, Web of Science, Embase, and Google Scholar for publications through 25 October 2023, with search terms including FIT, buffer, OC‐sensor, biomarkers, microbiome, microRNA (miR), colon, rectum, screening, neoplasm, and early detection. Studies employing home‐based collection samples using quantitative FIT first processed for haemoglobin were included. One author reviewed all articles; a second author completed a 20% full‐text audit to ensure adherence to eligibility criteria.
Results
A broad search yielded 1669 studies and application of eligibility criteria identified 18 relevant studies. Multiple protein, DNA/RNA, and microbiome biomarkers (notably haptoglobin, miR‐16, miR‐27a‐3p, miR‐92a, miR‐148a‐3p, miR‐223, miR‐421, let‐7b‐5p, and Tyzzerella 4 ) were associated with colorectal neoplasia. Furthermore, studies highlighted the short‐term stability of biomarkers for clinical use and long‐term stability for research purposes.
Conclusions
This scoping review summarises the framework and progress of research on stability of biomarkers in FIT residual buffer and their associations with colorectal neoplasia to guide opportunities for further confirmatory studies to enhance colorectal cancer screening.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Geisel School of Medicine at Dartmouth, Hanover, New Hampshire, USA.
- Department of Veterans Affairs Medical Center, White River Junction, Vermont, USA.
- The Dartmouth Institute for Health Policy and Clinical Practice, Lebanon, New Hampshire, USA.
ORCID profiles: Timothy McAuliffe, Douglas J Robertson
Funding
- Department of Veterans Affairs Medical Center, White River Junction, VT
Cite
APA
McAuliffe, T., Anderson, J. C., Larson, R. J., & Robertson, D. J. (2024). Systematic scoping review: Use of the faecal immunochemical test residual buffer to enhance colorectal cancer screening. Alimentary Pharmacology & Therapeutics. https://doi.org/10.1111/apt.17947
Vancouver
McAuliffe T, Anderson JC, Larson RJ, Robertson DJ. Systematic scoping review: Use of the faecal immunochemical test residual buffer to enhance colorectal cancer screening. Alimentary Pharmacology & Therapeutics. 2024. doi:10.1111/apt.17947
BibTeX
@article{McAuliffe2024,
author = {McAuliffe, Timothy and Anderson, Joseph C and Larson, Robin J and Robertson, Douglas J},
title = {Systematic scoping review: Use of the faecal immunochemical test residual buffer to enhance colorectal cancer screening},
journal = {Alimentary Pharmacology & Therapeutics},
year = {2024},
doi = {10.1111/apt.17947}
}
EUVIMED