EUVIMEDOpdag EUVIMED
Multizentrische StudieOpen access · CC BY 4.0

Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram‐negative bacteria: a NordicAST study

Truls M Leegaard iD, Ulrik S Justesen iD, Erika Matuschek iD, Christian G Giske iD, NordicAST study group on automated AST

APMIS · 2023-10 · 131 (10) · 543-551

DOI: 10.1111/apm.13346 ↗

At a glance

Multizentrische Studie in APMIS, published online on 2023-08-17. Written by Truls M Leegaard and 4 co-authors. Institution: Department of Microbiology and Infection Control, Akershus University Hospital, Lørenskog, Norway. Major MEDLINE topics: Anti-Bacterial Agents, Drug Resistance, Bacterial. Cited 8 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Automated testing of antimicrobial susceptibility is common in clinical microbiology laboratories but their ability to detect low‐level resistance has been questioned. This Nordic multicentre study aimed to evaluate the performance of commercially available automated AST systems. A phenotypically well‐characterised collection of gram‐negative bacilli ( Escherichia coli ( n = 7), Klebsiella pneumoniae ( n = 6) and Pseudomonas aeruginosa ( n = 7)) with and without resistance mechanisms was examined by Danish ( n = 1), Finnish ( n = 6), Norwegian ( n = 16) and Swedish ( n = 5) laboratories. Minimum inhibitory concentrations (MICs) were determined for 12 antimicrobials with automated systems and compared with MICs obtained with gold standard broth microdilution. The automated systems used were VITEK 2 ( n = 23), Phoenix ( n = 4), MicroScan ( n = 1), and ARIS ( n = 1). Very major errors were identified for six antimicrobials; cefotaxime (6.9%), meropenem (0.4%), ciprofloxacin (0.7%), ertapenem (4.3%), amikacin (3.4%) and colistin (6.4%). Categorical agreement of MIC for the automated systems compared to broth microdilution ranged from 83% for imipenem to 100% for ampicillin and trimethoprim‐sulfamethoxazole. The analysis revealed several important antimicrobials where resistance was underestimated, potentially with significant consequences in patient treatment. The results cast doubt on the use of automated AST in the management of patients with serious infections and suggests that more work is needed to define their limitations.

Subjects

MeSH terms (MEDLINE)

Anti-Bacterial AgentsDrug Resistance, BacterialHumansGram-Negative BacteriaAmikacinAmpicillinEscherichia coli

Author keywords

Automated antimicrobial susceptibility testingEUCASTNordicASTcarbapenemscephalosporinscolistin

Substances

Anti-Bacterial AgentsAmikacinAmpicillin

Authors and institutions

  • Department of Microbiology and Infection Control, Akershus University Hospital, Lørenskog, Norway.
  • Division of Medicine and Laboratory Sciences, University of Oslo, Oslo, Norway.
  • Department of Clinical Microbiology, Odense University Hospital, Odense, Denmark.
  • EUCAST Development Laboratory, Växjö, Sweden.
  • Department of Clinical Microbiology, MTC - Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.

ORCID profiles: Truls M Leegaard, Ulrik S Justesen, Erika Matuschek, Christian G Giske

Cite

APA

Leegaard, T. M., Justesen, U. S., Matuschek, E., Giske, C. G., & NordicAST study group on automated AST (2023). Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram‐negative bacteria: a NordicAST study. APMIS, 131(10), 543-551. https://doi.org/10.1111/apm.13346

Vancouver

Leegaard TM, Justesen US, Matuschek E, Giske CG, NordicAST study group on automated AST. Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram‐negative bacteria: a NordicAST study. APMIS. 2023;131(10):543-551. doi:10.1111/apm.13346

BibTeX
@article{Leegaard2023,
  author = {Leegaard, Truls M and Justesen, Ulrik S and Matuschek, Erika and Giske, Christian G and NordicAST study group on automated AST, NordicAST study group on automated AST},
  title = {Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram‐negative bacteria: a NordicAST study},
  journal = {APMIS},
  year = {2023},
  volume = {131},
  number = {10},
  pages = {543--551},
  doi = {10.1111/apm.13346}
}
Start for free →