Comparative diagnostic performance of digital and conventional tests for congenital red–green colour vision deficiency
Acta Ophthalmologica · 06.11.2026
DOI: 10.1111/aos.70265 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, online erschienen am 06.11.2026. Verfasst von Marina Vilella und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, Aragón Health Research Institute (IIS Aragon), Miguel Servet University Hospital, Zaragoza, Spain. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Instituto de Salud Carlos III, Ministerio de Ciencias y Universidades, Vicerrectorado de Transferencia e Innovación Tecnologica Universdad de Zaragoza.
Abstract (Originalsprache)
Purpose
To compare the diagnostic performance of the DIVE Colour Test for detecting congenital red–green (RG) colour vision deficiency, using the Colour Assessment and Diagnosis (CAD) test as the reference standard, with established conventional colour vision tests providing within‐sample benchmarks.
Methods
Sixty participants were enrolled in an observational study: 30 CAD‐confirmed normal trichromats and 30 participants with congenital RG deficiency. Each completed the CAD test, DIVE Colour Test (touch and eye‐tracking), Nagel anomaloscope, Ishihara 38 Plates Test and Roth 28‐Hue Test. Diagnostic accuracy against CAD was assessed using sensitivity, specificity and Cohen's kappa (k), both in right‐eye and binocular testing.
Results
In right‐eye testing, DIVE Touch achieved a sensitivity of 78.1% and a specificity of 100.0%, demonstrating substantial agreement with CAD ( κ = 0.77). In comparison, DIVE eye‐tracking showed lower sensitivity (53.1%) while maintaining high specificity (96.4%), yielding moderate agreement with CAD ( κ = 0.48). Regarding the binocular analysis: DIVE Touch yielded a sensitivity of 69.0%, a specificity of 100.0% and substantial agreement with CAD ( κ = 0.69). Among conventional tests versus CAD, Ishihara showed the highest sensitivity with complete specificity, the Nagel anomaloscope achieved substantial agreement, and the Roth 28‐Hue Test showed the lowest sensitivity for RG classification.
Conclusion
Diagnostic performance varied across colour vision tests. DIVE Touch showed high specificity, moderate sensitivity and substantial agreement with CAD, whereas DIVE Eye‐Tracking maintained high specificity but showed lower sensitivity and requires further optimisation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmology Department, Aragón Health Research Institute (IIS Aragon), Miguel Servet University Hospital, Zaragoza, Spain.
- Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
- Primary Care Interventions to Prevent Maternal and Child Chronic Diseases of Perinatal and Developmental Origin (RICORS), RD24/0013/0022, Instituto de Salud Carlos III, Madrid, Spain.
Förderung
- Instituto de Salud Carlos III
- Ministerio de Ciencias y Universidades
- Vicerrectorado de Transferencia e Innovación Tecnologica Universdad de Zaragoza
Zitieren
APA
Vilella, M., Fernandez-Fernandez, V. I., Carballo-Álvarez, J., Nieto-Bona, A., & Esteban-Ibañez, E. (2026). Comparative diagnostic performance of digital and conventional tests for congenital red–green colour vision deficiency. Acta Ophthalmologica. https://doi.org/10.1111/aos.70265
Vancouver
Vilella M, Fernandez-Fernandez VI, Carballo-Álvarez J, Nieto-Bona A, Esteban-Ibañez E. Comparative diagnostic performance of digital and conventional tests for congenital red–green colour vision deficiency. Acta Ophthalmologica. 2026. doi:10.1111/aos.70265
BibTeX
@article{Vilella2026,
author = {Vilella, Marina and Fernandez-Fernandez, Victor I and Carballo-Álvarez, Jesús and Nieto-Bona, Amelia and Esteban-Ibañez, Eduardo},
title = {Comparative diagnostic performance of digital and conventional tests for congenital red–green colour vision deficiency},
journal = {Acta Ophthalmologica},
year = {2026},
doi = {10.1111/aos.70265}
}
EUVIMED