EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy

Klemens Paul Kaiser iD, Julian Bucur iD, Tyll Jandewerth iD, Thomas Kohnen iD, Christoph Lwowski iD

Acta Ophthalmologica · 2025

DOI: 10.1111/aos.16741 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, 2025. Verfasst von Klemens Paul Kaiser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany. Hauptthemen laut MEDLINE: Lenses, Intraocular, Biometry, Phacoemulsification, Vitrectomy. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.

Methods

In this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe‐University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL‐FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with ±0.50, ±1.00 and ±2.00 dioptres (D) deviation from the target refraction was compared.

Results

In total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL‐FE group (1.02 D). Comparison between the AL‐FE and FE groups showed no statistically significant difference ( p = 0.712). Comparing eyes within ±0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL‐FE group (27.8%) and the FE group (26.6%).

Conclusion

Our results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two‐step procedure should always be strived for.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularBiometryPhacoemulsificationVitrectomyRefraction, OcularVisual AcuityLens Implantation, IntraocularHumansRetrospective StudiesFemaleMaleMiddle AgedAgedAxial Length, EyeAdultAged, 80 and overEndotamponade

Stichwörter der Autor:innen

IOL calculationfellow eyephacovitrectomyretinal detachment

Autor:innen und Institutionen

  • Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany.

ORCID-Profile: Klemens Paul Kaiser, Julian Bucur, Tyll Jandewerth, Thomas Kohnen, Christoph Lwowski

Zitieren

APA

Kaiser, K. P., Bucur, J., Jandewerth, T., Kohnen, T., & Lwowski, C. (2025). Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy. Acta Ophthalmologica. https://doi.org/10.1111/aos.16741

Vancouver

Kaiser KP, Bucur J, Jandewerth T, Kohnen T, Lwowski C. Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy. Acta Ophthalmologica. 2025. doi:10.1111/aos.16741

BibTeX
@article{Kaiser2025,
  author = {Kaiser, Klemens Paul and Bucur, Julian and Jandewerth, Tyll and Kohnen, Thomas and Lwowski, Christoph},
  title = {Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy},
  journal = {Acta Ophthalmologica},
  year = {2025},
  doi = {10.1111/aos.16741}
}
Kostenlos starten →