EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery

Anna Stage Vergmann iD, Frederik Emil Olsen, Anders Bo Nielsen, Anders Højslet Vestergaard iD, Ann Sofia Skou Thomsen, Lars Konge, Jakob Grauslund iD

Acta Ophthalmologica · 2024-09 · 102 (6) · 697-702

DOI: 10.1111/aos.16635 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Ophthalmologica, online erschienen am 25.01.2024. Verfasst von Anna Stage Vergmann und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Hauptthemen laut MEDLINE: Depth Perception, Vitreoretinal Surgery, Clinical Competence, Learning Curve. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Velux Fonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate whether individuals with long‐term reduced stereopsis were able to obtain the same level of surgical skills in simulated vitreoretinal surgery on the Eyesi Surgical Simulator as individuals with normal stereopsis.

Methods

Twenty‐four medical students were recruited and divided into two groups according to their degree of stereopsis: Group 1 ( n = 12) included subjects with normal stereopsis (60 arcsec or lower) and Group 2 ( n = 12) included subjects with reduced stereopsis (120 arcsec or higher). Stereopsis was tested using the TNO test (Lameris Ootech BV, Nieuwegein, the Netherlands). The participants were trained in virtual reality‐simulated vitreoretinal surgery and continuously measured using a test with solid validity evidence and a pre‐defined pass–fail score. All data were analysed using the Wilcoxon rank sum test.

Results

We observed no differences in overall performance scores for any of the four modules. The participants with reduced stereopsis used 5.8 more attempts in bimanual training ( p = 0.04), 8.8 more attempts in removal of posterior hyaloid ( p = 0.04), 9.1 more attempts in navigation training ( p = 0.20) and 0.3 fewer attempts in removal of internal limiting membrane ( p = 0.69).

Conclusion

The final performance scores on the Eyesi Surgical Simulator were independent of the degree of stereopsis. However, the number of attempts to achieve the pre‐defined pass–fail score increased significantly with reduced stereopsis in two of four modules. These results indicate that a high degree of stereopsis is not necessary to become proficient in microsurgery but may prolong the learning curve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Depth PerceptionVitreoretinal SurgeryClinical CompetenceLearning CurveHumansMaleFemaleOphthalmologyYoung AdultAdultStudents, Medical

Stichwörter der Autor:innen

Eyesistereopsissurgical performancesurgical simulationvirtual realityvitreoretinal surgery

Autor:innen und Institutionen

  • Department of Ophthalmology, Odense University Hospital, Odense, Denmark.
  • Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.
  • Regional Centre for Technical Simulation, Region of Southern Denmark, Odense, Denmark.
  • Department of Anesthesiology and Intensive Care, Odense University Hospital, Svendborg, Denmark.
  • Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark.
  • Copenhagen Academy for Medical Education and Simulation, Centre for HR and Education, Capital Region of Denmark, Copenhagen, Denmark.

ORCID-Profile: Anna Stage Vergmann, Anders Højslet Vestergaard, Jakob Grauslund

Förderung

  • Velux Fonden

Zitieren

APA

Vergmann, A. S., Olsen, F. E., Nielsen, A. B., Vestergaard, A. H., Thomsen, A. S. S., Konge, L., & Grauslund, J. (2024). Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery. Acta Ophthalmologica, 102(6), 697-702. https://doi.org/10.1111/aos.16635

Vancouver

Vergmann AS, Olsen FE, Nielsen AB, Vestergaard AH, Thomsen ASS, Konge L, et al. Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery. Acta Ophthalmologica. 2024;102(6):697-702. doi:10.1111/aos.16635

BibTeX
@article{Vergmann2024,
  author = {Vergmann, Anna Stage and Olsen, Frederik Emil and Nielsen, Anders Bo and Vestergaard, Anders Højslet and Thomsen, Ann Sofia Skou and Konge, Lars and Grauslund, Jakob},
  title = {Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery},
  journal = {Acta Ophthalmologica},
  year = {2024},
  volume = {102},
  number = {6},
  pages = {697--702},
  doi = {10.1111/aos.16635}
}
Kostenlos starten →