Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery
Acta Ophthalmologica · 2024-09 · 102 (6) · 697-702
DOI: 10.1111/aos.16635 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Ophthalmologica, online erschienen am 25.01.2024. Verfasst von Anna Stage Vergmann und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Hauptthemen laut MEDLINE: Depth Perception, Vitreoretinal Surgery, Clinical Competence, Learning Curve. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Velux Fonden.
Abstract (Originalsprache)
Purpose
To investigate whether individuals with long‐term reduced stereopsis were able to obtain the same level of surgical skills in simulated vitreoretinal surgery on the Eyesi Surgical Simulator as individuals with normal stereopsis.
Methods
Twenty‐four medical students were recruited and divided into two groups according to their degree of stereopsis: Group 1 ( n = 12) included subjects with normal stereopsis (60 arcsec or lower) and Group 2 ( n = 12) included subjects with reduced stereopsis (120 arcsec or higher). Stereopsis was tested using the TNO test (Lameris Ootech BV, Nieuwegein, the Netherlands). The participants were trained in virtual reality‐simulated vitreoretinal surgery and continuously measured using a test with solid validity evidence and a pre‐defined pass–fail score. All data were analysed using the Wilcoxon rank sum test.
Results
We observed no differences in overall performance scores for any of the four modules. The participants with reduced stereopsis used 5.8 more attempts in bimanual training ( p = 0.04), 8.8 more attempts in removal of posterior hyaloid ( p = 0.04), 9.1 more attempts in navigation training ( p = 0.20) and 0.3 fewer attempts in removal of internal limiting membrane ( p = 0.69).
Conclusion
The final performance scores on the Eyesi Surgical Simulator were independent of the degree of stereopsis. However, the number of attempts to achieve the pre‐defined pass–fail score increased significantly with reduced stereopsis in two of four modules. These results indicate that a high degree of stereopsis is not necessary to become proficient in microsurgery but may prolong the learning curve.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Odense University Hospital, Odense, Denmark.
- Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.
- Regional Centre for Technical Simulation, Region of Southern Denmark, Odense, Denmark.
- Department of Anesthesiology and Intensive Care, Odense University Hospital, Svendborg, Denmark.
- Department of Ophthalmology, Rigshospitalet, Glostrup, Denmark.
- Copenhagen Academy for Medical Education and Simulation, Centre for HR and Education, Capital Region of Denmark, Copenhagen, Denmark.
ORCID-Profile: Anna Stage Vergmann, Anders Højslet Vestergaard, Jakob Grauslund
Förderung
- Velux Fonden
Zitieren
APA
Vergmann, A. S., Olsen, F. E., Nielsen, A. B., Vestergaard, A. H., Thomsen, A. S. S., Konge, L., & Grauslund, J. (2024). Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery. Acta Ophthalmologica, 102(6), 697-702. https://doi.org/10.1111/aos.16635
Vancouver
Vergmann AS, Olsen FE, Nielsen AB, Vestergaard AH, Thomsen ASS, Konge L, et al. Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery. Acta Ophthalmologica. 2024;102(6):697-702. doi:10.1111/aos.16635
BibTeX
@article{Vergmann2024,
author = {Vergmann, Anna Stage and Olsen, Frederik Emil and Nielsen, Anders Bo and Vestergaard, Anders Højslet and Thomsen, Ann Sofia Skou and Konge, Lars and Grauslund, Jakob},
title = {Lack of stereopsis does not reduce surgical performance but prolongs the learning curve of vitreoretinal surgery},
journal = {Acta Ophthalmologica},
year = {2024},
volume = {102},
number = {6},
pages = {697--702},
doi = {10.1111/aos.16635}
}
EUVIMED