EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudieOpen Access · CC BY 4.0

3D vs. 2D-4 K: Performance and self-perception of laparoscopic novices in a randomized prospective teaching intervention using standard tasks and box trainers

Benny Kölbel, Julian Ragnitz, Kevin Schäle, Moritz Witzenhausen, Steffen Axt, Christian Beltzer

Langenbeck's Archives of Surgery · 2024

DOI: 10.1007/s00423-024-03515-5 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Langenbeck's Archives of Surgery, 2024. Verfasst von Benny Kölbel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of General, Visceral and Thoracic Surgery, German Armed Forces Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany. bennykoelbel@bundes…. Hauptthemen laut MEDLINE: Laparoscopy, Clinical Competence, Self Concept, Imaging, Three-Dimensional. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundeswehrkrankenhaus Ulm.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The use of three-dimensional (3D) laparoscopy in surgical practice and training has been an area of research and discussion. Studies have suggested that 3D vision can improve speed and precision compared to traditional two-dimensional (2D) displays, while other authors found no benefits on the learning curves of laparoscopic novices. Modern two-dimensional laparoscopy with a resolution of 3840 × 2160 pixels (2D-4 K) seems to improve laparoscopic view and helps learners orient without stereopsis. However, evidence comparing these systems for laparoscopic training is limited. Therefore, the impact of viewing mode (2D-4 K vs. 3D) on learning and task proficiency remains unclear.

Design

We performed a two-hour teaching intervention on basic laparoscopic skills for novices. In this parallel group randomized study, we randomly assigned learners to 2D-4 K or 3D teaching and performed tasks of increasing difficulty and complexity using standard laparoscopy box trainers. Before the last and most challenging task, learners had to crossover to the other laparoscopy setup. Our hypothesis was that learners would be faster and more precise when using a 3D setup. The primary endpoint was task proficiency measured by speed and failure rate. Secondary outcomes were performance using the viewing mode of the other group without familiarization, self-perception, and career aspirations before and after the teaching intervention, expressed on a Likert scale.

Setting

The study was performed by the Department of General, Visceral and Thoracic Surgery at the German Armed Forces Hospital Ulm, which is an academic teaching hospital of the University of Ulm.

Participants

Thirty-eight laparoscopic novices, including medical students and junior residents, participated voluntarily in this teaching intervention. Group allocation was performed via the virtual coin flip method. Apparently, participants and tutors were not blinded to group assignment. No formal approval by the ethics committee was needed for this noninvasive study in compliance with the World Medical Association Declaration of Helsinki as discussed with the ethics committee of the University of Ulm.

Results

Thirty-eight laparoscopy novices were randomized in the study. The 3D group ( n = 19) was significantly faster than the 2D-4 K group ( n = 19) ( p = .008) in a standard box trainer model, with 134.45 ± 41.45 s vs. 174.99 ± 54.03 s for task 1 and 195.97 ± 49.78 s vs. 276.56 ± 139.20 s for task 2, and the effect was consistent throughout the learning curve. The failure rate was not significantly affected by the viewing mode. After crossover to the other laparoscopy system, precision and time were not significantly different between the groups. Learners rated the difficulty of laparoscopy lower on a Likert scale after having two hours of basic laparoscopy training. The study was funded by the hospital’s teaching budget.

Conclusions

Laparoscopic novices can benefit from a 3D laparoscopy training setup. Exclusive 3D training prior to a complex task on a 2D-4 K setup does not negatively affect the learner’s performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopyClinical CompetenceSelf ConceptImaging, Three-DimensionalHumansMaleFemaleProspective StudiesAdultYoung AdultLearning CurveDepth Perception

Stichwörter der Autor:innen

2D-4 K3DLaparoscopySurgical training

Autor:innen und Institutionen

  • Department of General, Visceral and Thoracic Surgery, German Armed Forces Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany. bennykoelbel@bundeswehr.org.
  • School of Medicine, HMU Health and Medical University, Olympischer Weg 1, 14471, Potsdam, Germany.
  • Department for Trauma Surgery and Orthopedics, Reconstructive and Septic Surgery, Sportstraumatology, German Armed Forces Hospital Ulm, Oberer Eselsberg, 40, 89081, Ulm, Germany.
  • Department of General, Visceral and Thoracic Surgery, German Armed Forces Hospital Ulm, Oberer Eselsberg 40, 89081, Ulm, Germany.
  • Department of General, Visceral and Transplant Surgery, Tübingen University Hospital, Hoppe-Seyler-Str. 3, 72076, Tübingen, Germany.

Förderung

  • Bundeswehrkrankenhaus Ulm

Zitieren

APA

Kölbel, B., Ragnitz, J., Schäle, K., Witzenhausen, M., Axt, S., & Beltzer, C. (2024). 3D vs. 2D-4 K: Performance and self-perception of laparoscopic novices in a randomized prospective teaching intervention using standard tasks and box trainers. Langenbeck's Archives of Surgery. https://doi.org/10.1007/s00423-024-03515-5

Vancouver

Kölbel B, Ragnitz J, Schäle K, Witzenhausen M, Axt S, Beltzer C. 3D vs. 2D-4 K: Performance and self-perception of laparoscopic novices in a randomized prospective teaching intervention using standard tasks and box trainers. Langenbeck's Archives of Surgery. 2024. doi:10.1007/s00423-024-03515-5

BibTeX
@article{Klbel2024,
  author = {Kölbel, Benny and Ragnitz, Julian and Schäle, Kevin and Witzenhausen, Moritz and Axt, Steffen and Beltzer, Christian},
  title = {3D vs. 2D-4 K: Performance and self-perception of laparoscopic novices in a randomized prospective teaching intervention using standard tasks and box trainers},
  journal = {Langenbeck's Archives of Surgery},
  year = {2024},
  doi = {10.1007/s00423-024-03515-5}
}
Kostenlos starten →