EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation

Gaik Nersesian iD, Anna Stegmann, Daniel Lewin iD, Yuriy Hrytsyna, Leonard Pitts, Julius Kaemmel, Marian Kukucka, Alexander Mladenow, Lisa Garczarek, Julia Stein iD, Friedrich Kaufmann, Volkmar Falk und 2 weitere

Artificial Organs · 2026-08 · 50 (8) · 1164-1169

DOI: 10.1111/aor.70150 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Artificial Organs, online erschienen am 21.04.2026. Verfasst von Gaik Nersesian und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany. Hauptthemen laut MEDLINE: Heart-Assist Devices, Heart Failure, Monitoring, Intraoperative. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Left ventricular assist devices (LVAD) have become an established therapy for end‐stage heart failure over the last three decades. In currently available devices, the blood flow is estimated using a power consumption algorithm. In this study, intraoperative direct LVAD flow measurement with an ultrasonic flow probe was analyzed.

Methods

As part of our routine evaluation of optimal LVAD flow, intraoperative direct flow measurement at the outflow graft was performed using a 14‐mm ultrasonic flow probe. Direct LVAD flow measurements were performed at different speed levels: 4400 rpm, 4800 rpm, 5200 rpm, and the optimal flow setting before chest closure. In twenty consecutive patients who underwent a durable LVAD implantation via median sternotomy in our institution between January and April 2025, direct flow measurement was compared with the estimated flow provided by the device.

Results

Median age was 63 [60;68] years, 17 (85%) were male, 8 (40%) had a history of acute myocardial infarction. Temporary mechanical circulatory support with a microaxial flow pump was necessary in 8 (40%) patients prior to durable LVAD implantation. Destination therapy was indicated in 12 (60%) cases. Mean flows at 4400 rpm were 2.9 ± 0.3 and 3.4 ± 0.4 L/min calculated by the pump and measured by the probe, respectively. Mean difference between the measurements was 0.56 L/min (95% CI [0.40, 0.70], p < 0.001). Mean flows at 4800 rpm were 3.5 ± 0.3 and 4.1 ± 0.5 L/min, respectively. Mean difference between the measurements was 0.55 L/min (95% CI [0.33, 0.77], p < 0.001). Mean flows at 5200 rpm were 4.2 ± 0.3 and 4.7 ± 0.5 L/min, respectively. Mean difference between the measurements was 0.53 L/min (95% CI [0.40, 0.70], p = 0.001). Mean optimal speed for patients was 5400 rpm, mean difference between the measurements was 0.49 L/min (95% CI [0.23, 0.74], p = 0.001).

Conclusion

LVAD flow measured with an ultrasonic flow probe shows significantly higher results (approximately +0.5 L/min) compared to the flow estimated by the device. The difference remains constant at different LVAD speed modes. Intraoperative flow measurement employing an ultrasonic flow probe is a valuable tool for hemodynamic evaluation during implantation of a durable LVAD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart-Assist DevicesHeart FailureMonitoring, IntraoperativeHumansMaleMiddle AgedFemaleAgedAlgorithmsBlood Flow Velocity

Autor:innen und Institutionen

  • Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
  • DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany.
  • Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
  • Department of Cardioanesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
  • Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • Department of Health Sciences and Technology, Institute of Translational Medicine, Translational Cardiovascular Technologies, Swiss Federal Institute of Technology (ETH) Zurich, Zurich, Switzerland.

ORCID-Profile: Gaik Nersesian, Daniel Lewin, Julia Stein

Zitieren

APA

Nersesian, G., Stegmann, A., Lewin, D., Hrytsyna, Y., Pitts, L., Kaemmel, J., Kukucka, M., Mladenow, A., Garczarek, L., Stein, J., Kaufmann, F., Falk, V., Potapov, E., & Lanmueller, P. (2026). Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation. Artificial Organs, 50(8), 1164-1169. https://doi.org/10.1111/aor.70150

Vancouver

Nersesian G, Stegmann A, Lewin D, Hrytsyna Y, Pitts L, Kaemmel J, et al. Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation. Artificial Organs. 2026;50(8):1164-1169. doi:10.1111/aor.70150

BibTeX
@article{Nersesian2026,
  author = {Nersesian, Gaik and Stegmann, Anna and Lewin, Daniel and Hrytsyna, Yuriy and Pitts, Leonard and Kaemmel, Julius and Kukucka, Marian and Mladenow, Alexander and Garczarek, Lisa and Stein, Julia and Kaufmann, Friedrich and Falk, Volkmar and Potapov, Evgenij and Lanmueller, Pia},
  title = {Comparison of Intraoperative Doppler Flow Measurements and Algorithmic Flow Estimations in Patients Undergoing Durable Left Ventricular Assist Device Implantation},
  journal = {Artificial Organs},
  year = {2026},
  volume = {50},
  number = {8},
  pages = {1164--1169},
  doi = {10.1111/aor.70150}
}
Kostenlos starten →