Validierungsstudie in der Zeitschrift Artificial Organs, 2026. Verfasst von Anna Kathrin Assmann und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Heinrich-Heine-University, Düsseldorf, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Models, Cardiovascular, Extracorporeal Circulation, Aorta. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Deutsche Herzstiftung.
Abstract (Originalsprache)
Objectives
Although extracorporeal circulation (ECC) is routinely used in invasive cardiovascular medicine and can cause severe complications, the impact of ECC on arterial blood flow is not yet fully understood. This study aims to reveal actual bloodflow profiles during different ECC scenarios.
Methods
Twenty‐three New Zealand White rabbits underwent ECC by ante‐ ( n = 7) or retro‐grade ( n = 9) or physiological perfusion ( n = 7). Arterial blood flow profiles were assessed with a focus on cerebral and visceral perfusion. Numerical simulation models were tuned and validated based on magnetic resonance imaging (MRI).
Results
Ante‐ and retrograde ECC resulted in completely divergent aortic blood flow patterns. Supraaortic and visceral perfusions were not impaired during ante‐ or retro grade ECC. Excellent correlation of volume flow rates was achieved between MRI and simulations ( r = 0.98). Intima damage was observed in regions of high wall shear stress (WSS).
Conclusions
This is the first study assessing arterial blood flow during different ECC scenarios in a living organism, and additionally validating precise blood flow simulations by in vivo measurements. Retrograde ECC does not a priori impair cerebral perfusion. Individualized simulations may guide cannulation strategies aiming at minimization of ECC‐related complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Surgery, Heinrich-Heine-University, Düsseldorf, Germany.
- German Primate Center, Functional Imaging Laboratory, Göttingen, Germany.
- Department of Electrical Engineering and Information Technology, South Westphalia University of Applied Sciences, Hagen, Germany.
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Aachen, Germany.
ORCID-Profile: Anna Kathrin Assmann, Susann Boretius, Michael Neidlin, Alexander Assmann
Förderung
- Deutsche Forschungsgemeinschaft
- Deutsche Herzstiftung
Zitieren
APA
Assmann, A. K., Reimers, S., Schrauder, J. S., Qu, L., Yin, X., Moussavi, A., Lichtenberg, A., Boretius, S., Neidlin, M., & Assmann, A. (2026). Validation of Aortic Blood Flow Simulations During Extracorporeal Circulation Using Phase Contrast Magnetic Resonance Imaging. Artificial Organs. https://doi.org/10.1111/aor.70136
Vancouver
Assmann AK, Reimers S, Schrauder JS, Qu L, Yin X, Moussavi A, et al. Validation of Aortic Blood Flow Simulations During Extracorporeal Circulation Using Phase Contrast Magnetic Resonance Imaging. Artificial Organs. 2026. doi:10.1111/aor.70136
BibTeX
@article{Assmann2026,
author = {Assmann, Anna Kathrin and Reimers, Sinje and Schrauder, Jonah S and Qu, Lei and Yin, Xiangge and Moussavi, Amir and Lichtenberg, Artur and Boretius, Susann and Neidlin, Michael and Assmann, Alexander},
title = {Validation of Aortic Blood Flow Simulations During Extracorporeal Circulation Using Phase Contrast Magnetic Resonance Imaging},
journal = {Artificial Organs},
year = {2026},
doi = {10.1111/aor.70136}
}
EUVIMED