EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

In Vitro and In Vivo Evaluation of Decellularized Porcine Femoral Aorta Reinforced With Electrospun Coarse Polycaprolactone Fibers for Vascular Graft Application

Hyun-Yong Lee, Md Abdullah Al Fahad, Myeongki Park, Hoe-Jin Kang, Nusrat Jahan, Prayas Chakma Shanto, Hyeyoung Kim, Byong-Taek Lee, Sang Ho Bae

Artificial Organs · 2026-06 · 50 (6) · 813-824

DOI: 10.1111/aor.70106 ↗

At a glance

Journal article in Artificial Organs, published online on 2026-03-12. Written by Hyun-Yong Lee and 8 co-authors. Institution: Department of Surgery, Soonchunhyang University Cheonan Hospital, Cheonan, Republic of Korea. Major MEDLINE topics: Polyesters, Blood Vessel Prosthesis, Decellularized Extracellular Matrix, Aorta. 36 references. The full text is freely available (open access, CC BY 4.0). Funded by: Ministry of Science and ICT, South Korea, National Research Foundation of Korea, Soonchunhyang University, Republic of Korea.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The clinical translation of small‐diameter vascular grafts (SDVGs) is still limited due to severe complications, including thrombosis, intimal hyperplasia, and arteriosclerosis, commonly associated with synthetic polymer‐based grafts. To address these challenges, combining synthetic polymers with naturally derived extracellular matrices (ECMs) offers a promising strategy to enhance biofunctionality and remodeling potential.

Method

This study developed a composite vascular graft by electrospinning a polycaprolactone (PCL) fibrous outer layer onto decellularized porcine femoral aorta extracellular matrix (PECM), generating a hybrid PCL‐PECM graft. Decellularization was validated using H&E staining and DNA quantification, ensuring effective cellular removal without compromising protein content. Scanning electron microscopy (SEM) was used to evaluate the interface between PCL and PECM. Mechanical properties were assessed via tensile testing. Hemocompatibility was evaluated by hemolysis testing and blood clotting index (%BCI). In vitro biocompatibility was assessed using cell culture assays, and in vivo remodeling was evaluated through subcutaneous implantation in a rat model, followed by histological analysis.

Results

H&E staining and DNA analysis confirmed complete decellularization. SEM images revealed no delamination between layers, and the PCL layer significantly enhanced the mechanical strength of the graft. Hemolysis ratio remained below 5%, and %BCI exceeded 80%, indicating excellent hemocompatibility. In vitro studies confirmed cytocompatibility, while histological staining of explanted grafts showed robust cell infiltration and ECM remodeling.

Conclusion

The PCL‐PECM vascular graft demonstrates excellent structural integrity, mechanical performance, hemocompatibility, and remodeling potential, indicating its promise as a next‐generation SDVG.

Subjects

MeSH terms (MEDLINE)

PolyestersBlood Vessel ProsthesisDecellularized Extracellular MatrixAortaFemoral ArteryBioprosthesisAnimalsSwineMaterials TestingRatsTissue EngineeringProsthesis DesignExtracellular MatrixHumansTissue ScaffoldsBlood Vessel Prosthesis ImplantationMale

Author keywords

decellularized ECMelectrospinningsmall‐diameter vascular graft

Substances

PolyesterspolycaprolactoneDecellularized Extracellular Matrix

Authors and institutions

  • Department of Surgery, Soonchunhyang University Cheonan Hospital, Cheonan, Republic of Korea.
  • Department of Regenerative Medicine, College of Medicine, Soonchunhyang University, Cheonan, Republic of Korea.
  • Institute of Tissue Regeneration, Soonchunhyang University, Cheonan, Republic of Korea.

Funding

  • Ministry of Science and ICT, South Korea
  • National Research Foundation of Korea
  • Soonchunhyang University, Republic of Korea
  • Soonchunhyang University

Cite

APA

Lee, H. Y., Fahad, M. A. A., Park, M., Kang, H. J., Jahan, N., Shanto, P. C., Kim, H., Lee, B. T., & Bae, S. H. (2026). In Vitro and In Vivo Evaluation of Decellularized Porcine Femoral Aorta Reinforced With Electrospun Coarse Polycaprolactone Fibers for Vascular Graft Application. Artificial Organs, 50(6), 813-824. https://doi.org/10.1111/aor.70106

Vancouver

Lee HY, Fahad MAA, Park M, Kang HJ, Jahan N, Shanto PC, et al. In Vitro and In Vivo Evaluation of Decellularized Porcine Femoral Aorta Reinforced With Electrospun Coarse Polycaprolactone Fibers for Vascular Graft Application. Artificial Organs. 2026;50(6):813-824. doi:10.1111/aor.70106

BibTeX
@article{Lee2026,
  author = {Lee, Hyun-Yong and Fahad, Md Abdullah Al and Park, Myeongki and Kang, Hoe-Jin and Jahan, Nusrat and Shanto, Prayas Chakma and Kim, Hyeyoung and Lee, Byong-Taek and Bae, Sang Ho},
  title = {In Vitro and In Vivo Evaluation of Decellularized Porcine Femoral Aorta Reinforced With Electrospun Coarse Polycaprolactone Fibers for Vascular Graft Application},
  journal = {Artificial Organs},
  year = {2026},
  volume = {50},
  number = {6},
  pages = {813--824},
  doi = {10.1111/aor.70106}
}
Start for free →