Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids
Artificial Organs · 2026
DOI: 10.1111/aor.70089 ↗At a glance
Journal article in Artificial Organs, 2026. Written by Michael G Megaly and 11 co-authors. Institution: Division of Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA. Major MEDLINE topics: Hepatocytes, Spheroids, Cellular, Propidium. 20 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, National Science Foundation, Biostasis Research Institute.
Abstract (original language)
Background
Three‐dimensional (3D) hepatocyte spheroids better recapitulate liver microenvironments than monolayers, but robust, high‐throughput viability assessment remains challenging because of diffusion limits and stain penetration.
Objective
To evaluate a simple imaging‐based approach that quantifies spheroid viability by measuring acridine orange (AO) and propidium iodide (PI) fluorescence and computing a PI brightness‐to‐area ratio.
Methods
Rat hepatocyte spheroids were formed on a rocker, stained with AO/PI, and imaged on an inverted fluorescence microscope with fixed exposure settings. We prepared mixtures representing nominal 0%, 30%, 50%, 70%, and 100% viable spheroids and analyzed the relationship between viability and the PI brightness‐to‐area ratio. Statistical analyses included one‐way ANOVA with Tukey's HSD and simple linear regression with diagnostic checks. A urea/DNA functional assay as well as a small blinded study both served as an orthogonal validation.
Results
The PI brightness‐to‐area ratio decreased with increasing percent viable cells (Pearson r = −0.99; R 2 = 0.98; p = 1.81 × 10 −4 ). Residuals were approximately normal and homoscedastic. Urea/DNA strongly and positively correlated with viability ( r = 1.00; p = 1.10 × 10 −4 ; R 2 = 1.00) with regression equation: y = 9.049444 × 10 −6 x + 3.036814 × 10 −5 . All blinded studies were within 10% of established viability; average difference between mean observer estimates and ground truth was +1.7 percentage points (range −3.7 to +10).
Conclusions
A fixed‐setting AO/PI imaging workflow yields a rapid, accessible proxy for hepatocyte spheroid viability that correlates with a functional readout. This approach is well‐suited to high‐throughput screening and method optimization.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Division of Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA.
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota, USA.
- Schulze Diabetes Institute, University of Minnesota, Minneapolis, Minnesota, USA.
- Department of Biological Sciences, University of North Carolina, Charlotte, North Carolina, USA.
- Department of Mechanical Engineering and Engineering Science, University of North Carolina, Charlotte, North Carolina, USA.
- Institute for Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota, USA.
ORCID profiles: John C Bischof, Erik B Finger
Funding
- NIH HHS
- National Science Foundation
- Biostasis Research Institute
- National Institutes of Health
Cite
APA
Megaly, M. G., Tobolt, D., Namsrai, B. E., Fisher, B., Chen, A. A. D., Rao, J. S., Ramesh, S., Chimedtseren, A., Clemens, M., Lee, C. Y., Bischof, J. C., & Finger, E. B. (2026). Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids. Artificial Organs. https://doi.org/10.1111/aor.70089
Vancouver
Megaly MG, Tobolt D, Namsrai BE, Fisher B, Chen AAD, Rao JS, et al. Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids. Artificial Organs. 2026. doi:10.1111/aor.70089
BibTeX
@article{Megaly2026,
author = {Megaly, Michael G and Tobolt, Diane and Namsrai, Bat-Erdene and Fisher, Benjamin and Chen, Anthony An-Fa Dahm and Rao, Joseph Sushil and Ramesh, Srivasupradha and Chimedtseren, Anudari and Clemens, Mark and Lee, Charles Y and Bischof, John C and Finger, Erik B},
title = {Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids},
journal = {Artificial Organs},
year = {2026},
doi = {10.1111/aor.70089}
}
EUVIMED