EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids

Michael G Megaly, Diane Tobolt, Bat-Erdene Namsrai, Benjamin Fisher, Anthony An-Fa Dahm Chen, Joseph Sushil Rao, Srivasupradha Ramesh, Anudari Chimedtseren, Mark Clemens, Charles Y Lee, John C Bischof iD, Erik B Finger iD

Artificial Organs · 2026

DOI: 10.1111/aor.70089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Artificial Organs, 2026. Verfasst von Michael G Megaly und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA. Hauptthemen laut MEDLINE: Hepatocytes, Spheroids, Cellular, Propidium. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Science Foundation, Biostasis Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Three‐dimensional (3D) hepatocyte spheroids better recapitulate liver microenvironments than monolayers, but robust, high‐throughput viability assessment remains challenging because of diffusion limits and stain penetration.

Objective

To evaluate a simple imaging‐based approach that quantifies spheroid viability by measuring acridine orange (AO) and propidium iodide (PI) fluorescence and computing a PI brightness‐to‐area ratio.

Methods

Rat hepatocyte spheroids were formed on a rocker, stained with AO/PI, and imaged on an inverted fluorescence microscope with fixed exposure settings. We prepared mixtures representing nominal 0%, 30%, 50%, 70%, and 100% viable spheroids and analyzed the relationship between viability and the PI brightness‐to‐area ratio. Statistical analyses included one‐way ANOVA with Tukey's HSD and simple linear regression with diagnostic checks. A urea/DNA functional assay as well as a small blinded study both served as an orthogonal validation.

Results

The PI brightness‐to‐area ratio decreased with increasing percent viable cells (Pearson r = −0.99; R 2 = 0.98; p = 1.81 × 10 −4 ). Residuals were approximately normal and homoscedastic. Urea/DNA strongly and positively correlated with viability ( r = 1.00; p = 1.10 × 10 −4 ; R 2 = 1.00) with regression equation: y = 9.049444 × 10 −6 x + 3.036814 × 10 −5 . All blinded studies were within 10% of established viability; average difference between mean observer estimates and ground truth was +1.7 percentage points (range −3.7 to +10).

Conclusions

A fixed‐setting AO/PI imaging workflow yields a rapid, accessible proxy for hepatocyte spheroid viability that correlates with a functional readout. This approach is well‐suited to high‐throughput screening and method optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HepatocytesSpheroids, CellularPropidiumAnimalsCell SurvivalRatsMicroscopy, FluorescenceAcridine OrangeHigh-Throughput Screening AssaysFluorescent Dyes

Stichwörter der Autor:innen

bioartificial liverfluorescence microscopyhepatocyte spheroidsorganoidviability

Substanzen

PropidiumAcridine OrangeFluorescent Dyes

Autor:innen und Institutionen

  • Division of Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota, USA.
  • Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota, USA.
  • Schulze Diabetes Institute, University of Minnesota, Minneapolis, Minnesota, USA.
  • Department of Biological Sciences, University of North Carolina, Charlotte, North Carolina, USA.
  • Department of Mechanical Engineering and Engineering Science, University of North Carolina, Charlotte, North Carolina, USA.
  • Institute for Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota, USA.

ORCID-Profile: John C Bischof, Erik B Finger

Förderung

  • NIH HHS
  • National Science Foundation
  • Biostasis Research Institute
  • National Institutes of Health

Zitieren

APA

Megaly, M. G., Tobolt, D., Namsrai, B. E., Fisher, B., Chen, A. A. D., Rao, J. S., Ramesh, S., Chimedtseren, A., Clemens, M., Lee, C. Y., Bischof, J. C., & Finger, E. B. (2026). Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids. Artificial Organs. https://doi.org/10.1111/aor.70089

Vancouver

Megaly MG, Tobolt D, Namsrai BE, Fisher B, Chen AAD, Rao JS, et al. Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids. Artificial Organs. 2026. doi:10.1111/aor.70089

BibTeX
@article{Megaly2026,
  author = {Megaly, Michael G and Tobolt, Diane and Namsrai, Bat-Erdene and Fisher, Benjamin and Chen, Anthony An-Fa Dahm and Rao, Joseph Sushil and Ramesh, Srivasupradha and Chimedtseren, Anudari and Clemens, Mark and Lee, Charles Y and Bischof, John C and Finger, Erik B},
  title = {Measuring Propidium Iodide Brightness as a Function of Viability: A High‐Throughput Quantitative Assessment of Hepatic Spheroids},
  journal = {Artificial Organs},
  year = {2026},
  doi = {10.1111/aor.70089}
}
Kostenlos starten →